Publicación:
Microdureza superficial de resinas Bulk Fill según tiempo de fotopolimerización de diferentes lámparas LED

dc.contributor.advisorTay Chu Jon, Lidia Yilenges_ES
dc.contributor.advisorDelgado Cotrina, Leyla Antoinettees_ES
dc.contributor.authorTrujillo Flores, Stephanyes_ES
dc.date.accessioned2025-01-31T21:30:52Z
dc.date.available2025-01-31T21:30:52Z
dc.date.issued2024
dc.description.abstractLa Microdureza superficial de las resinas Bulk Fill pueden ser influenciadas de diversas maneras ya sea por el tipo de lámpara, composición de la resina o tiempo de fotopolimerización En base a ello, el objetivo de este estudio fue evaluar la Microdureza superficial de las resinas Bulk Fill luego de la fotopolimerización con diferentes lámparas LED en tiempos de 20 y 40 segundos. El diseño del estudio fue experimental in vitro, las muestras estuvieron conformadas por especímenes de resina de forma circular con diámetro de 5 mm x4 mm de altura (n=5), se evaluaron las resinas Filtek Bulk Fill (3M) color A2 y Tetric N Ceram Bulk Fill (Ivoclar) color A2 fotopolimerizadas con las lámparas Valo™ Grand (Ultradent), Elipar™ Deep Cure-L (3M), Woodpecker Led F (Woodpecker), Bluephase N MC (Ivoclar) durante 20 y 40 segundos. Se evaluó la microdureza de todas las muestras en la parte superior e inferior, con el microdurómetro de Vickers. Se utilizó la prueba Anova/Tukey para poder determinar las diferencias significativas entre los valores obtenidos según las resinas, las lámparas de fotopolimerización y el tiempo. El nivel de confianza fue de un 95% con un valor de p<0.05. La resina Bulk Fill (3M) color A2 tuvo mejores valores de Microdureza con la lámpara Woodpecker Led F (Woodpecker) presentando diferencia significativa respecto a las demás lámparas a los 20 segundos y la resina Tetric N Ceram Bulk Fill (Ivoclar) color A2 presentó mejores valores con la lámpara Valo™ Grand (Ultradent) con diferencia significativa a los 20 segundos. Los valores de Microdureza superficial fueron aceptables en ambas resinas pero se identificó que pueden variar de acuerdo al tipo de lámpara y a la composición (coiniciadores, monómeros) que presenta cada resina.es_ES
dc.description.abstractThe surface microhardness of Bulk Fill resins can be influenced in several ways either by the type of lamp, resin composition or light curing time. Based on this, the objective of this study was to evaluate the surface microhardness of Bulk Fill resins after light curing with different LED lamps at times of 20 and 40 seconds. The design of the study was experimental in vitro, the samples consisted of circular resin specimens with a diameter of 5 mm x 4 mm in height (n=5), Filtek Filtek One Bulk Fill (3M) color A2 and Tetric N Ceram Bulk Fill (Ivoclar) color A2 resins light cured with Valo™ Grand (Ultradent), Elipar™ Deep Cure-L (3M), Woodpecker Led F (Woodpecker), Bluephase N MC (Ivoclar) lamps for 20 and 40 seconds were evaluated. The microhardness of all specimens was evaluated at the top and bottom, using Vickers microhardness tester. The Anova/Tukey test was used to determine the significant differences between the values obtained according to resins, light-curing lamps and time. The confidence level was 95% with a value of p<0.05. The Bulk Fill resin (3M) color A2 had better Microhardness values with the Woodpecker Led F lamp (Woodpecker) presenting a significant difference with respect to the other lamps at 20 seconds and the Tetric N Ceram Bulk Fill resin (Ivoclar) color A2 presented better values with the Valo™ Grand lamp (Ultradent) with a significant difference at 20 seconds. The surface microhardness values were acceptable in both resins but it was identified that they can vary according to the type of lamp and the composition (co-initiators, monomers) that each resin presents.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.other213943es_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12866/16632
dc.language.isospaes_ES
dc.publisherUniversidad Peruana Cayetano Herediaes_ES
dc.publisher.countryPEes_ES
dc.rightshttps://purl.org/coar/access_right/c_abf2es_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.eses_ES
dc.subjectResinases_ES
dc.subjectPolimerizaciónes_ES
dc.subjectLámparases_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14es_ES
dc.titleMicrodureza superficial de resinas Bulk Fill según tiempo de fotopolimerización de diferentes lámparas LEDes_ES
dc.title.alternativeSurface microhardness of Bulk Fill resins according to the light curing time of different LED lampses_ES
dc.typehttp://purl.org/coar/resource_type/c_46eces_ES
dspace.entity.typePublication
renati.advisor.dni41875787
renati.advisor.dni10193841
renati.advisor.orcidhttps://orcid.org/0000-0002-1656-2804es_ES
renati.advisor.orcidhttps://orcid.org/0000-0002-3027-178Xes_ES
renati.author.dni47549131
renati.discipline911209es_ES
renati.jurorMas Lopez, Janettes_ES
renati.jurorHenostroza Quintans, Nataliaes_ES
renati.jurorOrdoñez Reyes, Leydi Fiorelaes_ES
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidades_ES
renati.typehttps://purl.org/pe-repo/renati/type#tesises_ES
thesis.degree.disciplineOdontología Restauradora y Estéticaes_ES
thesis.degree.grantorUniversidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neiraes_ES
thesis.degree.nameSegunda Especialidad Profesional en Odontología Restauradora y Estéticaes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Microdureza_TrujilloFlores_Stephany.pdf
Tamaño:
375.99 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones