Publicación:
Concordancia de los sistemas digitales Nemoscan, Omnicam e InEosX 3D para la medición de 6 piezas y 4 distancias dentarias en niveles de apiñamiento

dc.contributor.advisorSalazar Silva, Raúl Fernandoes_ES
dc.contributor.authorBravo Calderón, Manuel Estuardoes_ES
dc.date.accessioned2022-06-24T21:55:38Z
dc.date.available2022-06-24T21:55:38Z
dc.date.issued2022
dc.description.abstractLos escáneres digitales cada vez se encuentran más al alcance de los profesionales de ortodoncia por lo que es necesario evaluar su concordancia considerando las condiciones de apiñamiento de la arcada de los pacientes, estudios realizados hasta ahora no han evaluado a los escáneres intra (Omnicam) y extraorales (InEosX y Nemoscan) con respecto al gold standard. El presente estudio tiene el propósito de establecer la fiabilidad de los sistemas digitales NEMOSCAN, OMNICAM e INEOSX 3D para la medición de piezas y arcadas dentarias con y sin apiñamiento dental. A través de dos observadores que anteriormente no han utilizado escáneres 3D se realizó impresiones digitales en las arcadas de 36 pacientes, de cada uno se obtuvo 10 mediciones (agrupadas en cuatro grupos nueve pacientes según el nivel de apiñamiento). Luego de una capacitación, cada observador realizó su propia impresión. Se evaluó la concordancia de las mediciones entre cada sistema digital con el gold standard con el Coeficiente de Correlación Intraclase (CCI). Los resultados muestran que los promedios de todos los casos presentan una fiabilidad muy alta tanto para las medidas intraobservador como para las medidas interobservador (CCI˃0,800). Así como se comparó las medidas de estos dos observadores con la prueba ANOVA de un factor para determinar la precisión de dichas mediciones sin encontrar diferencias significativas (p˂0,001). Se ha establecido que la fiabilidad de los sistemas digitales NEMOSCAN, OMNICAM e INEOSX 3D para la medición de piezas y arcadas dentarias con y sin apiñamiento dental es la misma que la medición realizada con el gold standard mediante calibrador digital manual. La ausencia de apiñamiento, así como la presencia de apiñamiento leve, moderado o severo, no constituye un factor que afecte a la fiabilidad de las mediciones.es_ES
dc.description.abstractDigital scanners are increasingly available to orthodontic professionals, so it is necessary to evaluate their concordance considering the crowding conditions of the patients' arches, studies carried out so far have not evaluated intra (Omnicam ) and extraoral (InEosX and Nemoscan) with respect to the gold standard. The present study aims to establish the reliability of the NEMOSCAN, OMNICAM and INEOSX 3D digital systems for the measurement of teeth and dental arches with and without dental crowding. Digital impressions were made in the arches of 36 patients by two observers who had not previously used 3D scanners; 10 measurements were obtained from each one (nine patients grouped into four groups according to the level of crowding). After a training, each observer made his own impression. The concordance of the measurements between each digital system was evaluated with the gold standard with the Intraclass Correlation Coefficient (ICC). The results show that the averages of all the cases present a very high reliability for both the intraobserver measures and the interobserver measures (ICC˃0,800). In addition, the measurements of these two observers were compared with the one-way ANOVA test to determine the precision of the measurements without finding significant differences (p˂0,001). It has been established that the reliability of the NEMOSCAN, OMNICAM and INEOSX 3D digital systems for the measurement of teeth and dental arches with and without dental crowding is the same as the measurement performed with the gold standard using a manual digital caliper. The absence of crowding, as well as the presence of mild, moderate or severe crowding, does not constitute a factor that affects the reliability of the measurements.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.other203498es_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12866/11829
dc.language.isospaes_ES
dc.publisherUniversidad Peruana Cayetano Herediaes_ES
dc.publisher.countryPEes_ES
dc.rightshttps://purl.org/coar/access_right/c_abf2es_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.eses_ES
dc.subjectApiñamientoes_ES
dc.subjectConfiabilidades_ES
dc.subjectEscáner Dental 3Des_ES
dc.subjectPrecisiónes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.12es_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14es_ES
dc.titleConcordancia de los sistemas digitales Nemoscan, Omnicam e InEosX 3D para la medición de 6 piezas y 4 distancias dentarias en niveles de apiñamientoes_ES
dc.typehttp://purl.org/coar/resource_type/c_db06es_ES
dspace.entity.typePublication
renati.advisor.dni07566516
renati.advisor.orcidhttps://orcid.org/0000-0002-9815-3309es_ES
renati.author.dni102137460
renati.discipline911018es_ES
renati.jurorCabezas Bernhardt, Gerson Oswaldoes_ES
renati.jurorCastillo Cevallos, Jorge Luises_ES
renati.jurorCarbajal Arroyo, Luz Auroraes_ES
renati.jurorCastillo Andamayo, Diana Esmeraldaes_ES
renati.levelhttps://purl.org/pe-repo/renati/level#doctores_ES
renati.typehttps://purl.org/pe-repo/renati/type#tesises_ES
thesis.degree.disciplineEstomatologíaes_ES
thesis.degree.grantorUniversidad Peruana Cayetano Heredia. Escuela de Posgrado Víctor Alzamora Castroes_ES
thesis.degree.nameDoctor en Estomatologíaes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Concordancia_BravoCalderon_Manuel.pdf
Tamaño:
1.06 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción: