Publicación: Técnicas de reducción de la dosis de radiación y del volumen de contraste en la angiotomografía pulmonar en adultos con sospecha de embolismo pulmonar: una revisión de alcance
| dc.contributor.advisor | Mosquera Vergaray, Natalia Isabel | |
| dc.contributor.author | Alave Cardenas, Brisa Flaviana | |
| dc.contributor.author | Laguna Cardenas, Lisset Valeria | |
| dc.contributor.author | Roman Zuñiga, Miguel Angel | |
| dc.date.accessioned | 2026-04-30T15:44:14Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Antecedentes: El embolismo pulmonar (EP) es una condición potencialmente mortal y el tercer síndrome cardiovascular agudo más frecuente a nivel mundial. La angiografía pulmonar por tomografía computarizada (CTPA) es el estándar de referencia para su diagnóstico; sin embargo, implica la exposición a radiación ionizante y al uso de medio de contraste yodado. Objetivo: Mapear la evidencia disponible sobre técnicas para reducir la dosis de radiación y el volumen de medio de contraste (MC) en estudios de CTPA en adultos con sospecha de EP, sin comprometer la calidad de imagen. Materiales y métodos: Se realizó una revisión de alcance siguiendo las guías del Joanna Briggs Institute y PRISMA-ScR. Se incluyeron estudios con texto completo publicados entre 2012 a 2025, identificados en MEDLINE, Embase, Scopus, SciELO, Google Académico y ALICIA, conforme a los criterios PCC. Resultados: Se incluyeron nueve estudios. Las estrategias más frecuentes fueron el uso de bajo kVp, adquisiciones de alto pitch, modo dual-source simultáneo (SimDS) y tomografía con detectores de conteo de fotones (PCD-CT), generalmente combinadas con reconstrucción iterativa. La dosis efectiva varió entre 0.4 a 2.6 mSv con reducciones de hasta más del 70 % y el volumen de MC se redujo entre 25 % a 66 % (20–25 ml). La mayoría de estudios reportó una atenuación arterial pulmonar superior a 250 UH y parámetros de calidad de imagen aceptables. Conclusiones: Las técnicas identificadas permiten reducir de manera significativa la dosis de radiación y el volumen de MC en CTPA, manteniendo los parámetros de calidad de imagen. | |
| dc.description.abstract | Background: Pulmonary embolism (PE) is a potentially life-threatening condition and the third most frequent acute cardiovascular syndrome worldwide. Computed tomography pulmonary angiography (CTPA) is the reference standard for its diagnosis; however, it involves exposure to ionizing radiation and the use of iodinated contrast media. Objective: To map the available evidence on techniques aimed at reducing radiation dose and contrast volume in CTPA examinations in adults with suspected PE, without compromising image quality. Materials and Methods: A scoping review was conducted following the Joanna Briggs Institute guidelines and the PRISMA - ScR statement. Full-text studies published between 2012 and 2025 were included and identified in MEDLINE, Embase, Scopus, SciELO, Google Scholar, and ALICIA, according to PCC criteria. Results: Nine studies were included. The most frequently reported strategies were low tube voltage (kVp), high-pitch acquisitions, simultaneous dual-source (SimDS) mode, and photon-counting detector CT (PCD - CT), generally combined with iterative reconstruction. Effective dose ranged from 0.4 to 2.6 mSv with reductions of up to more than 70 %, while contrast volume was reduced by 25 % to 66 % (20 – 25 ml). Most studies reported pulmonary arterial attenuation values above 250 HU and acceptable image quality parameters. Conclusions: The identified techniques allow a significant reduction in radiation dose and contrast volume in CTPA while maintaining diagnostic image quality. | |
| dc.format | application/pdf | |
| dc.identifier.other | 219770 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12866/19388 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Peruana Cayetano Heredia | |
| dc.publisher.country | PE | |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | Https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | |
| dc.subject | Embolismo Pulmonar | |
| dc.subject | Angiografía Pulmonar | |
| dc.subject | Dosis de Radiación | |
| dc.subject | Medio de Contraste | |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.12 | |
| dc.title | Técnicas de reducción de la dosis de radiación y del volumen de contraste en la angiotomografía pulmonar en adultos con sospecha de embolismo pulmonar: una revisión de alcance | |
| dc.title.alternative | Radiation dose and contrast media volume reduction techniques in computed tomography pulmonary angiography in adults with suspected pulmonary embolism: a scoping review | |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Trabajo de grado - Pregrado | |
| dspace.entity.type | Publication | |
| renati.advisor.dni | 09396333 | |
| renati.advisor.orcid | https://orcid.org/0000-0003-1372-4449 | |
| renati.author.dni | 71486275 | |
| renati.author.dni | 71128699 | |
| renati.author.dni | 46347185 | |
| renati.discipline | 915076 | |
| renati.juror | Bravo Puente, Guillermo | |
| renati.juror | Mucha Lopez, Diana Carolina | |
| renati.juror | Tasayco Perez, Evelyn Tatiana | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | |
| renati.type | https://purl.org/pe-repo/renati/type#tesis | |
| thesis.degree.discipline | Tecnología Médica en la Especialidad de Radiología | |
| thesis.degree.grantor | Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado | |
| thesis.degree.name | Licenciado en Tecnología Médica en la Especialidad de Radiología |
