Publicación:
Oído absoluto y medidas P300: una revisión sistemática y metaanálisis

dc.contributor.advisorQuispe Gutierrez, Antonio Marty
dc.contributor.authorLazaro Cruz, Jose Gabriel
dc.date.accessioned2026-11-12T20:37:10Z
dc.date.issued2026
dc.date.other2026-11-11
dc.description.abstractEl oído absoluto (OA) es una habilidad musical poco frecuente (0,01% de la población) que permite identificar o reproducir tonos musicales sin una referencia externa. Esta capacidad se ha vinculado al componente P300 del electroencefalograma (EEG). El presente estudio llevó a cabo una revisión sistemática y un meta-análisis para examinar la relación entre el OA y las medidas de amplitud y latencia del P300 siguiendo las directrices PRISMA. Se incluyeron estudios que compararan participantes con y sin OA en tareas auditivas que midieran la amplitud y la latencia del P300. Se calcularon tamaños de efecto estandarizados (g de Hedges) para el meta-análisis utilizando modelos de efectos fijos y aleatorios, según correspondiera. Se evaluó la heterogeneidad entre los estudios (I², Q), así como la influencia de estudios individuales y el posible sesgo de publicación mediante gráficos en embudo. Se incluyeron un total de 15estudios que comprendieron 490 participantes. El metaanálisis mostró una reducción significativa de la latencia del P300 en el grupo con OA en comparación con el grupo sin esta habilidad (g = -0,42, IC 95% [-0,63 – -0,21], p< 0,001), con heterogeneidad moderada (I² = 34%). En contraste, el análisis de la amplitud del P300 no reveló diferencias estadísticamente significativas entre los grupos (g = -0,43, IC 95% [-0,86 – 0,00], p = 0,05), presentando una heterogeneidad sustancial (I² = 77%). Estos hallazgos indican que el OA se asocia con una reducción en la latencia del P300, lo que sugiere un procesamiento auditivo más eficiente y automático en las personas con esta habilidad. Sin embargo, la evidencia sobre las diferencias en la amplitud del P300 sigue siendo inconclusa. Los resultados respaldan la existencia de mecanismos neurocognitivos diferenciados en individuos con OA.spa
dc.description.abstractAbsolute pitch (AP) is a rare musical ability (0.01% of the population) that allows individuals to identify or reproduce musical tones without an external reference. This ability has been linked to the P300 component of the electroencephalogram(EEG). The present study conducted a systematic review and meta-analysis to examine the relationship between AP and the amplitude and latency measures of the P300, following PRISMA guidelines. Studies comparing participants with and without AP in auditory tasks that assessed P300 amplitude and latency were included. Standardized effect sizes (Hedges’ g) were computed for the meta-analysis using both fixed- and random-effects models, as appropriate. Heterogeneity across studies (I², Q) was assessed, along with the influence of individual studies and potential publication bias through funnel plot analysis. A total of 15 studies comprising 490 participants were included. The meta-analysis of P300 latency showed a significant reduction in the AP group compared to the non-AP group (g = -0.42, 95% CI [-0.63, -0.21], p < .001), with moderate heterogeneity (I² = 34%). In contrast, the analysis of P300 amplitude revealed no statistically significant differences between groups (g = -0.43, 95% CI [-0.86,0.00], p = .05), with substantial heterogeneity (I² = 77%). These findings suggest that AP is associated with a reduction in P300 latency, indicating more efficient and automatic auditory processing among individuals with this ability. However, evidence regarding differences in P300 amplitude remains in conclusive. Overall, the results support the existence of distinct neurocognitive mechanisms in individuals with absolute pitch.eng
dc.formatapplication/pdf
dc.format.size7.99 MB
dc.identifier.other218821
dc.identifier.urihttps://hdl.handle.net/20.500.12866/25265
dc.language.isospa
dc.publisherUniversidad Peruana Cayetano Heredia
dc.publisher.countryPE
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.subjectElectroencefalograma (EEG)spa
dc.subjectP300spa
dc.subjectOído Absoluto (OA)spa
dc.subjectOído Relativospa
dc.subjectTono Musicalspa
dc.subjectRevisión Sistemáticaspa
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.25
dc.titleOído absoluto y medidas P300: una revisión sistemática y metaanálisisspa
dc.typehttp://purl.org/coar/resource_type/c_bdcc
dc.type.localTrabajo de grado - Maestría
dspace.entity.typePublication
renati.advisor.dni10774189
renati.advisor.orcidhttps://orcid.org/0000-0003-2100-7423
renati.author.dni46873394
renati.discipline91902637
renati.jurorZavaleta Martinez-Vargas, Alfonso
renati.jurorUmeres Caceres, Hugo Felix
renati.jurorGallo Lopez Aliaga, Carla Maria
renati.levelhttps://purl.org/pe-repo/renati/level#maestro
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineNeurociencias
thesis.degree.grantorUniversidad Peruana Cayetano Heredia. Escuela de Posgrado Víctor Alzamora Castro
thesis.degree.nameMaestro en Neurociencia

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Oido_LazaroCruz_Jose.pdf
Tamaño:
8 MB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
58 B
Formato:
Item-specific license agreed upon to submission
Descripción: