Publicación:
Evaluación de rugosidad de red cerámica circonio - sílice infiltrada en una matriz de resina CAD/CAM expuesta a dos medios erosivos. Estudio in vitro

dc.contributor.advisorChavez Alayo, Pablo Armandoes_ES
dc.contributor.advisorDelgado Cotrina, Leyla Antoinettees_ES
dc.contributor.authorFernandez Shilta, Nataly Lissethes_ES
dc.contributor.authorGil Farcio, Diana Mariliaes_ES
dc.date.accessioned2026-02-02T18:26:26Z
dc.date.available2026-02-02T18:26:26Z
dc.date.issued2026
dc.description.abstractAntecedentes: La erosión dental se determina como la pérdida de estructura dental debido a causas químicas no bacterianas, mediante disolución por sustancias intrínsecas y extrínsecas. La erosión dental ahora se reconoce como un problema mundial de salud oral pública junto con la caries dental y la enfermedad periodontal. Los materiales cerámicos de matriz de resina han evolucionado, los cuales se han visto acompañados por un aumento significativo en su aplicación en odontología restauradora y estética. La red cerámica circonio - sílice infiltrada por matriz de resina, es un material adaptado a diferentes matrices orgánicas, está compuesto por un 85 % de partículas cerámicas ultrafinas de circonio y sílice incrustadas en una matriz polimérica de metacrilato BISGMA y TEGDMA. La exposición de los materiales cerámicos de matriz de resina a medios erosivos es un tema cuestionable por el deterioro que sufriría sobre su superficie poniendo en duda sus propiedades mecánicas; por esta razón se realiza el presente estudio evaluando la propiedad de rugosidad de los materiales cerámicas a base de matriz de resina. Objetivo: Evaluar la rugosidad superficial de una red cerámica circonio - sílice infiltrada en una matriz de resina CAD/CAM expuesta a dos medios erosivos durante 24 horas. Métodos y Materiales: Estudio experimental in vitro. Se utilizaron 30 muestras de red cerámica circonio - sílice infiltrada por matriz de resina (Shofu Block HC), los cuales se clasificaron en 3 grupos. El primer grupo se sometió al ácido gástrico simulado, el segundo a ácido cítrico y el tercer grupo a saliva artificial, los tres grupos se sumergieron por un tiempo total de 24 horas. Resultados: Los medios ácidos (ácido gástrico simulado y ácido cítrico) provocaron un aumento en la rugosidad superficial del material, en contraste con la saliva artificial que no produjo cambios significativos. Sin embargo, este incremento fue menor al umbral crítico para afectar su funcionalidad clínica. Estos resultados indican que la exposición a ácidos puede alterar la superficie de la cerámica, pero sin comprometer su desempeño clínico. Conclusiones: El estudio mostró que tanto el ácido gástrico simulado como el ácido cítrico afectan la rugosidad superficial de la cerámica de matriz de resina, sin diferencias significativas entre ellos, confirmando la hipótesis del estudio. Estos resultados apoyan el uso de este material en pacientes con riesgo de erosión ácida, aunque se sugieren investigaciones futuras para evaluar su durabilidad a largo plazo.es_ES
dc.description.abstractBackground: Dental erosion is defined as the loss of tooth structure due to non-bacterial chemical causes, through dissolution by intrinsic and extrinsic substances. Dental erosion is now recognized as a global public oral health problem, along with dental caries and periodontal disease. Resin matrix ceramic materials have evolved, which has been accompanied by a significant increase in their application in restorative and aesthetic dentistry. The zirconium-silica ceramic network infiltrated by a resin matrix is a material adapted to different organic matrices. It is composed of 85% ultrafine zirconium and silica ceramic particles embedded in a polymeric matrix of BISGMA and TEGDMA methacrylate. The exposure of resin matrix ceramic materials to erosive media is a questionable issue due to the deterioration that would occur on their surface, calling into question their mechanical properties; For this reason, the present study was conducted to evaluate the roughness property of resin matrix-based ceramic materials. Objective: Evaluate the surface roughness of a zirconium-silica ceramic network infiltrated into a CAD/CAM resin matrix exposed to two erosive media for 24 hours. Methods and Materials: In vitro experimental study. Thirty samples of resin-infiltrated zirconia-silica ceramic network (Shofu Block HC) were used and classified into three groups. The first group was exposed to simulated gastric acid, the second to citric acid, and the third to artificial saliva. All three groups were immersed for a total of 24 hours. Results: The acidic media (simulated gastric acid and citric acid) caused an increase in the surface roughness of the material, in contrast to artificial saliva, which did not produce significant changes. However, this increase was less than the critical threshold for affecting its clinical functionality. These results indicate that exposure to acids can alter the surface of the ceramic, but without compromising its clinical performance. Conclusions: The study showed that both simulated gastric acid and citric acid affect the surface roughness of the resin matrix ceramic, with no significant differences between them confirming the study's hypothesis, these results support the use of this material in patients at risk of acid erosion, although future research is suggested to assess its long-term durability.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.other214227es_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12866/18115
dc.language.isospaes_ES
dc.publisherUniversidad Peruana Cayetano Herediaes_ES
dc.publisher.countryPEes_ES
dc.rightshttps://purl.org/coar/access_right/c_abf2es_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.eses_ES
dc.subjectÁcido Cítricoes_ES
dc.subjectÁcido Gástricoes_ES
dc.subjectCerámicaes_ES
dc.subjectErosión de Dienteses_ES
dc.subjectPropiedades de Superficiees_ES
dc.subjectResina Compuestases_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14es_ES
dc.titleEvaluación de rugosidad de red cerámica circonio - sílice infiltrada en una matriz de resina CAD/CAM expuesta a dos medios erosivos. Estudio in vitroes_ES
dc.title.alternativeEvaluation of the surface roughness of zirconia-silica ceramic network infiltrated in a CAD/CAM resin matrix exposed to two erosive media. An in vitro studyes_ES
dc.typehttp://purl.org/coar/resource_type/c_46eces_ES
dspace.entity.typePublication
renati.advisor.dni41664570
renati.advisor.dni10193841
renati.advisor.orcidhttps://orcid.org/0009-0003-2158-1684es_ES
renati.advisor.orcidhttps://orcid.org/0000-0002-3027-178Xes_ES
renati.author.dni46942159
renati.author.dni70942152
renati.discipline911199es_ES
renati.jurorQuintana Del Solar, Martin Gilbertoes_ES
renati.jurorCastillo Andamayo, Diana Esmeraldaes_ES
renati.jurorFlores Mas, Ricardo Jorgees_ES
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidades_ES
renati.typehttps://purl.org/pe-repo/renati/type#tesises_ES
thesis.degree.disciplineRehabilitación Orales_ES
thesis.degree.grantorUniversidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neiraes_ES
thesis.degree.nameSegunda Especialidad Profesional en Rehabilitación Orales_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Evaluacion_FernandezShilta_Nataly.pdf
Tamaño:
875.9 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones