Publicación:
Promedio de la presión arterial sistólica diurna en el monitoreo continuo durante 1 hora versus el monitoreo ambulatorio durante 24 horas: un estudio comparativo en pacientes hipertensos controlados

dc.contributor.advisorMedina Palomino, Félix Alvaroes_ES
dc.contributor.advisorLoza Munarriz, César Antonioes_ES
dc.contributor.authorDelgado Cueto, Alvaro Alonsoes_ES
dc.contributor.authorDel Castillo Miranda, Jose Carloses_ES
dc.date.accessioned2023-01-17T17:53:03Z
dc.date.available2023-01-17T17:53:03Z
dc.date.issued2022
dc.description.abstractAntecedentes: El monitoreo ambulatorio de la presión arterial de 24 horas (MAPA 24h) es la mejor herramienta para evaluar el control de la PA en pacientes hipertensos. Sin embargo, presenta limitaciones como son su alto costo, incomodidad durante tomas y restringido número de pacientes evaluados. Objetivos: Comparar el promedio de la presión arterial sistólica (PAS) diurna mediante el monitoreo continuo de la PA por 1 hora (MCPA-1) versus el MAPA 24h, y secundariamente el promedio de la presión arterial diastólica (PAD) diurna. Además, comparar la PAS y PAD diurna del MAPA 24h versus el MCPA de 30 minutos (MCPA-30) y el MAPA 24h versus la medición de la PA en consulta. Metodología: Estudio descriptivo transversal prospectivo. Se reclutaron pacientes hipertensos controlados del servicio de cardiología del Hospital Cayetano Heredia (HCH) y se les aplicó los criterios de inclusión y exclusión. Se usó la prueba t de Student pareada para las medias de los promedios de la PAS y PAD y además se halló el coeficiente de correlación de Pearson (rp). Resultados: De los 51 participantes, 40 fueron incluidos para el análisis. Fueron 75% mujeres, con edad promedio de 65.88 ± 8.61 años, con obesidad (55%) y en monoterapia farmacológica (52.5%). La diferencia de medias no fue significativa (p=0.258) para la PAS diurna entre el MAPA 24h y MCPA-1 (-2.07 mmHg) pero, sí fue significativo (p=0.009) para la PAD (-2.66 mmHg). Se halló una fuerte correlación (0.5≤ rp ≤1) para la PAS (rp=0.56) y PAD (rp=0.82) diurna entre el MAPA 24h y MCPA-1, estadísticamente significativa (p<0.05). Conclusiones: El promedio de la PAS diurna entre el MCPA-1 y MAPA 24h fue estadísticamente comparable al no existir diferencias significativas entre las mediciones de la PA con ambos métodos.es_ES
dc.description.abstractBackground: 24-hour ambulatory blood pressure monitoring (24h ABPM) is the best tool for evaluating BP control in hypertensive patients. However, it has limitations such as its high cost, discomfort during recordings, and restricted number of patients evaluated. Objectives: Our study aimed to compare the average daytime systolic blood pressure (SBP) using continuous BP monitoring for 1 hour (CBPM-1) versus 24h ABPM and secondarily, the average daytime diastolic blood pressure (DBP). Furthermore, to compare daytime SBP and DBP between 24h ABPM versus 30-minute CBPM (CBPM-30) and 24h ABPM versus BP measurement in the office. Methodology: We conducted a prospective crosssectional descriptive study. Controlled hypertensive patients were recruited from the cardiology service of Hospital Cayetano Heredia (HCH), and the inclusion and exclusion criteria were applied. The paired Student's t-test was used for the means of the SBP and DBP averages, and the Pearson correlation coefficient (rp) was also found. Results: Of the 51 participants recruited, 40 were included in the final analysis. 75% of them were women, with a mean age of 65.88 ± 8.61 years old, with obesity (55%), and in pharmacological monotherapy (52.5%). The mean difference was not significant (p=0.258) for daytime SBP between 24h ABPM and CBPM-1 (-2.07 mmHg), but it was significant (p=0.009) for DBP (-2.66 mmHg). A strong correlation (0.5≤ rp ≤1) was found for daytime SBP (rp=0.56) and DBP (rp=0.82) between the 24h ABPM and CBPM-1, statistically significant (p<0.05). Conclusions: The average daytime SBP between the CBPM-1 and ABPM 24h was statistically comparable as there were no significant differences between both methods.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.other202787es_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12866/13033
dc.language.isospaes_ES
dc.publisherUniversidad Peruana Cayetano Herediaes_ES
dc.publisher.countryPEes_ES
dc.rightshttps://purl.org/coar/access_right/c_abf2es_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.eses_ES
dc.subjectHipertensiónes_ES
dc.subjectMonitoreo Ambulatorio de la Presión Arteriales_ES
dc.subjectPresión Sanguíneaes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.04es_ES
dc.titlePromedio de la presión arterial sistólica diurna en el monitoreo continuo durante 1 hora versus el monitoreo ambulatorio durante 24 horas: un estudio comparativo en pacientes hipertensos controladoses_ES
dc.title.alternativeAverage daytime systolic blood pressure in 1-hour continuous blood pressure monitoring versus 24-hour ambulatory blood pressure monitoring: a comparative study in controlled hypertensive patientses_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1fes_ES
dspace.entity.typePublication
renati.advisor.dni08421895
renati.advisor.dni21456043
renati.advisor.orcidhttps://orcid.org/0000-0002-5854-1032es_ES
renati.advisor.orcidhttps://orcid.org/0000-0003-4545-9969es_ES
renati.author.dni70489817
renati.author.dni76217806
renati.discipline912016es_ES
renati.jurorAnchante Hernández, Henry Alexanderes_ES
renati.jurorGuillén López, Otto Barnabyes_ES
renati.jurorMas Ubillús, Guilianaes_ES
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_ES
renati.typehttps://purl.org/pe-repo/renati/type#trabajoDeInvestigaciones_ES
thesis.degree.disciplineMedicinaes_ES
thesis.degree.grantorUniversidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtadoes_ES
thesis.degree.nameMédico Cirujanoes_ES

Archivos

Bloque original

Mostrando 1 - 4 de 4
Cargando...
Miniatura
Nombre:
Promedio_DelgadoCueto_Alvaro.pdf
Tamaño:
1.35 MB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
Formulario_DelgadoCueto_Alvaro.pdf
Tamaño:
239.55 KB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
Turnitin_DelgadoCueto_Alvaro.pdf
Tamaño:
2.47 MB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
ActaJurado_DelgadoCueto_Alvaro.pdf
Tamaño:
440.92 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones