Publicación: Adaptación de cofias metálicas confeccionadas con la técnica de fusión selectiva láser según la relación ángulo de convergencia, altura de muñón y tipo de impresión digital
| dc.contributor.advisor | Quintana del Solar, Martin Gilberto | |
| dc.contributor.advisor | Delgado Cotrina, Leyla Antoniette | |
| dc.contributor.author | Gonzales Valdivia, Javier Alexander | |
| dc.date.accessioned | 2026-08-18T17:23:09Z | |
| dc.date.issued | 2026 | |
| dc.date.other | 2026-08-13 | |
| dc.description.abstract | Introducción: La adaptación marginal en prótesis dentales es fundamental para prevenir complicaciones biológicas como caries secundarias e inflamación gingival. Factores como la altura del muñón, el ángulo de convergencia total (ACT) y los métodos de impresión influyen directamente en la precisión del ajuste del margen protésico. El análisis de estas variables permite optimizar el desempeño clínico y abordar vacíos en la literatura sobre tecnologías digitales emergentes. Objetivo: Evaluar el efecto de la altura del muñón, el ángulo de convergencia total y dos tipos de impresión en la adaptación marginal de coronas dentales. Materiales y métodos: Estudio experimental in vitro con 8 grupos según altura vestibular (4 mm y 6 mm), ACT (12° y 16°) y tipo de impresión (convencional con escáner de laboratorio e intraoral). La adaptación se evaluó con el método de réplica de silicona, realizando cortes vestibulopalatinos y mesiodistales. Las mediciones se efectuaron con estereomicroscopio a 40X, obteniendo 6 registros por corte en superficies cervical, axial y oclusal. Se calcularon medias y desviaciones estándar, aplicando ANOVA y prueba de Tukey bajo un supuesto de normalidad. Resultados: La adaptación marginal dependió del tipo de escáner, el ACT y la altura del muñón. El escáner intraoral presentó menor discrepancia marginal independientemente de las variables (p<0.05). En la adaptación axial, el escáner de laboratorio mostró mejores resultados a 16°, mientras que el intraoral no evidenció diferencias significativas. En la adaptación oclusal, el escáner intraoral mostró menores discrepancias, siendo la mayor en el escáner de laboratorio a 6 mm y ACT de 12°. Conclusiones: La adaptación de cofias metálicas fabricadas mediante SLM está determinada por la interacción de las variables estudiadas. El escáner intraoral mostró mejor desempeño, evidenciando un comportamiento multifactorial. | spa |
| dc.description.abstract | Introduction: Marginal adaptation in dental prostheses is essential to prevent biological complications such as secondary caries and gingival inflammation. Factors such as abutment height, total convergence angle (TCA), and impression methods directly influence the accuracy of the prosthetic margin fit. The analysis of these variables allows optimization of clinical performance and helps address gaps in the literature related to emerging digital technologies. Objective: To evaluate the effect of abutment height, total convergence angle, and two types of impression techniques on the marginal adaptation of dental crowns. Materials and Methods: An in vitro experimental study was conducted with eight groups based on vestibular height (4 mm and 6 mm), TCA (12° and 16°), and type of impression (conventional using a laboratory scanner and intraoral scanning). Adaptation was assessed using the silicone replica technique, with vestibulopalatal and mesiodistal sectioning. Measurements were performed using a stereomicroscope at 40× magnification, obtaining six records per section on cervical, axial, and occlusal surfaces. Means and standard deviations were calculated, and ANOVA and Tukey tests were applied under the assumption of normality. Results: Marginal adaptation depended on the type of scanner, TCA, and abutment height. The intraoral scanner showed lower marginal discrepancy regardless of the variables (p < 0.05). For axial adaptation, the laboratory scanner showed better results at 16°, whereas the intraoral scanner showed no significant differences. In occlusal adaptation, the intraoral scanner showed lower discrepancies, while the highest discrepancy was observed with the laboratory scanner at 6 mm and a TCA of 12°. Conclusions: The adaptation of metal copings fabricated by selective laser melting (SLM) isdetermined by the interaction of the studied variables. The intraoral scanner demonstrated better performance, highlighting the multifactorial nature of marginal adaptation. | eng |
| dc.format | application/pdf | |
| dc.format.size | 1,535 KB | |
| dc.identifier.other | 218726 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12866/24850 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Peruana Cayetano Heredia | |
| dc.publisher.country | PE | |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | |
| dc.subject | Adaptación | spa |
| dc.subject | Láseres de Estado Sólido | spa |
| dc.subject | Diseño Asistido por Computadora | spa |
| dc.subject | Técnica de Impresión Dental | spa |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | |
| dc.title | Adaptación de cofias metálicas confeccionadas con la técnica de fusión selectiva láser según la relación ángulo de convergencia, altura de muñón y tipo de impresión digital | spa |
| dc.type | http://purl.org/coar/resource_type/c_bdcc | |
| dc.type.local | Trabajo de grado - Maestría | |
| dspace.entity.type | Publication | |
| renati.advisor.dni | 07613737 | |
| renati.advisor.dni | 10193841 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-7087-7874 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-3027-178X | |
| renati.author.dni | 40446528 | |
| renati.discipline | 91102657 | |
| renati.juror | Balarezo Razzeto, Jose Antonio | |
| renati.juror | Evangelista Alva, Alexis | |
| renati.juror | Olivera Chacón, Hanz | |
| renati.level | https://purl.org/pe-repo/renati/level#maestro | |
| renati.type | https://purl.org/pe-repo/renati/type#tesis | |
| thesis.degree.discipline | Rehabilitación Oral | |
| thesis.degree.grantor | Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira | |
| thesis.degree.name | Maestro en Rehabilitación Oral |
