dc.contributor.advisor |
Domínguez, John Alexis |
es_ES |
dc.contributor.author |
Arroyo Bazan, Maricielo |
es_ES |
dc.contributor.author |
Ayala Gonzales, Erika Patricia |
es_ES |
dc.contributor.author |
Palacios Suarez, Patricia Alondra |
es_ES |
dc.date.accessioned |
2021-12-21T20:28:25Z |
|
dc.date.available |
2021-12-21T20:28:25Z |
|
dc.date.issued |
2021 |
|
dc.identifier.other |
201460 |
es_ES |
dc.identifier.uri |
https://hdl.handle.net/20.500.12866/10332 |
|
dc.description.abstract |
Objetivo: El objetivo de este proyecto de investigación fue evaluar el ángulo de contacto del adhesivo Monobond Etch & Prime en la cerámica disilicato de litio tratado con dos concentraciones de ácido fluorhídrico y dos tipos de limpieza. Materiales y métodos: Estudio experimental in vitro. Se realizó una cantidad de muestras de discos de cerámica obteniendo 4 grupos (n = 6 discos por grupo de trabajo) (9). Cada uno de estos discos fue colocado en el interior de un tubo de policloruro de vinilo (PVC) y fijadas con resina acrílica con la superficie fresada expuesta para los tratamientos de superficie, dividiéndose en grupos: ácido fluorhídrico al 5% y 10%. Luego se sometieron bajo dos tipos de limpieza (ultrasonido y ácido fosfórico) y se colocó una gota de Monobond Etch & Prime. Después del tratamiento de superficie los grupos de trabajo fueron evaluados mediante la metodología de ángulo de contacto en el software ImageJ usando los complementos LB-ADSA (lb), contac angle (ca), angle tool (at). Resultados: El menor ángulo de contacto se obtuvo con la concentración de ácido fluorhídrico al 5% y una limpieza de ácido fosfórico con la medición lb= 21.71±0.7A este fue significativamente menor (p<0.05) comparado con las diferentes mediciones ca = 19.85±4.7A, at= 21.09±4.77A donde no se obtuvo diferencia significativa. (p>0.05) Conclusión: El menor ángulo de contacto en cerámicas disilicato de litio se obtuvo con la concentración de ácido Fluorhídrico al 5% y la limpieza de ácido fosfórico. |
es_ES |
dc.description.abstract |
Objective: The objective of this research project was to evaluate the contact angle of the Monobond Etch & Prime adhesive in lithium disilicate ceramic treated with two concentrations of hydrofluoric acid and two types of cleaning. Materials and methods: Study experimental in vitro. A number of IPS Emax2 ceramic disc samples were made, obtaining 4 groups (n = 6 per working group) (9). Each of these discs was placed inside a polyvinyl chloride (PVC) tube and fixed with acrylic resin with the exposed milled surfce for surface treatments, divided in groups: 5% hydrofluoric acid and 10%. Then they underwent two types of cleaning (ultrasound and phosphoric acid) and a drop of Monobond Etch & Prime was placed. After the surface treatment the working groups were evaluated using the contact angle methodology in the ImageJ software using the LB-ADSA (lb), contac angle (ca), angle tool (at) complements. Results: The lowest contact angle was obtained with the concentration of hydrofluoric acid at 5% and a cleaning of phosphoric acid with the measurement lb=21.71 ± 0.7A, this was significantly lower (p <0.05) compared to the different measurements ca= 19.85 ± 4.7A, at= 21.09 ± 4.77A where no significant difference was obtained. (p> 0.05). Conclusions: The lowest contact angle in lithium disilicate ceramics was obtained with the concentration of hydrofluoric acid at 5% and the cleaning of phosphoric acid. |
es_ES |
dc.format |
application/pdf |
es_ES |
dc.language.iso |
spa |
es_ES |
dc.publisher |
Universidad Peruana Cayetano Heredia |
es_ES |
dc.rights |
info:eu-repo/semantics/openAccess |
es_ES |
dc.rights.uri |
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es |
es_ES |
dc.subject |
Cerámica |
es_ES |
dc.subject |
Äcido Fluorhídrico |
es_ES |
dc.subject |
Software |
es_ES |
dc.title |
Efecto de la concentración de ácido fluorhídrico sobre el ángulo de contacto de un adhesivo monocomponente en cerámica de disilicato de litio |
es_ES |
dc.title.alternative |
Effect of hydrofluoric acid concentration on the contact angle of a single component adhesive in lithium disilicate ceramic |
es_ES |
dc.type |
info:eu-repo/semantics/bachelorThesis |
es_ES |
thesis.degree.name |
Cirujano Dentista |
es_ES |
thesis.degree.grantor |
Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira |
es_ES |
thesis.degree.discipline |
Estomatología |
es_ES |
dc.publisher.country |
PE |
es_ES |
dc.subject.ocde |
http://purl.org/pe-repo/ocde/ford#2.05.02 |
es_ES |
dc.subject.ocde |
http://purl.org/pe-repo/ocde/ford#3.02.14 |
es_ES |
renati.author.dni |
71329880 |
|
renati.author.dni |
70184213 |
|
renati.author.dni |
76090391 |
|
renati.advisor.orcid |
https://orcid.org/0000-0002-8214-6171 |
es_ES |
renati.advisor.dni |
001202335 |
|
renati.type |
http://purl.org/pe-repo/renati/type#trabajoDeInvestigacion |
es_ES |
renati.level |
http://purl.org/pe-repo/renati/nivel#tituloProfesional |
es_ES |
renati.discipline |
911016 |
es_ES |
renati.juror |
Delgado Cotrina, Leyla Antoinette |
es_ES |
renati.juror |
Paz Mayuri, Carlos Alberto |
es_ES |
renati.juror |
Orejuela Ramírez, Francisco José |
es_ES |