Universidad Peruana Cayetano Heredia

Efecto de la concentración de ácido fluorhídrico sobre el ángulo de contacto de un adhesivo monocomponente en cerámica de disilicato de litio

Mostrar el registro sencillo del ítem

dc.contributor.advisor Domínguez, John Alexis es_ES
dc.contributor.author Arroyo Bazan, Maricielo es_ES
dc.contributor.author Ayala Gonzales, Erika Patricia es_ES
dc.contributor.author Palacios Suarez, Patricia Alondra es_ES
dc.date.accessioned 2021-12-21T20:28:25Z
dc.date.available 2021-12-21T20:28:25Z
dc.date.issued 2021
dc.identifier.other 201460 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/10332
dc.description.abstract Objetivo: El objetivo de este proyecto de investigación fue evaluar el ángulo de contacto del adhesivo Monobond Etch & Prime en la cerámica disilicato de litio tratado con dos concentraciones de ácido fluorhídrico y dos tipos de limpieza. Materiales y métodos: Estudio experimental in vitro. Se realizó una cantidad de muestras de discos de cerámica obteniendo 4 grupos (n = 6 discos por grupo de trabajo) (9). Cada uno de estos discos fue colocado en el interior de un tubo de policloruro de vinilo (PVC) y fijadas con resina acrílica con la superficie fresada expuesta para los tratamientos de superficie, dividiéndose en grupos: ácido fluorhídrico al 5% y 10%. Luego se sometieron bajo dos tipos de limpieza (ultrasonido y ácido fosfórico) y se colocó una gota de Monobond Etch & Prime. Después del tratamiento de superficie los grupos de trabajo fueron evaluados mediante la metodología de ángulo de contacto en el software ImageJ usando los complementos LB-ADSA (lb), contac angle (ca), angle tool (at). Resultados: El menor ángulo de contacto se obtuvo con la concentración de ácido fluorhídrico al 5% y una limpieza de ácido fosfórico con la medición lb= 21.71±0.7A este fue significativamente menor (p<0.05) comparado con las diferentes mediciones ca = 19.85±4.7A, at= 21.09±4.77A donde no se obtuvo diferencia significativa. (p>0.05) Conclusión: El menor ángulo de contacto en cerámicas disilicato de litio se obtuvo con la concentración de ácido Fluorhídrico al 5% y la limpieza de ácido fosfórico. es_ES
dc.description.abstract Objective: The objective of this research project was to evaluate the contact angle of the Monobond Etch & Prime adhesive in lithium disilicate ceramic treated with two concentrations of hydrofluoric acid and two types of cleaning. Materials and methods: Study experimental in vitro. A number of IPS Emax2 ceramic disc samples were made, obtaining 4 groups (n = 6 per working group) (9). Each of these discs was placed inside a polyvinyl chloride (PVC) tube and fixed with acrylic resin with the exposed milled surfce for surface treatments, divided in groups: 5% hydrofluoric acid and 10%. Then they underwent two types of cleaning (ultrasound and phosphoric acid) and a drop of Monobond Etch & Prime was placed. After the surface treatment the working groups were evaluated using the contact angle methodology in the ImageJ software using the LB-ADSA (lb), contac angle (ca), angle tool (at) complements. Results: The lowest contact angle was obtained with the concentration of hydrofluoric acid at 5% and a cleaning of phosphoric acid with the measurement lb=21.71 ± 0.7A, this was significantly lower (p <0.05) compared to the different measurements ca= 19.85 ± 4.7A, at= 21.09 ± 4.77A where no significant difference was obtained. (p> 0.05). Conclusions: The lowest contact angle in lithium disilicate ceramics was obtained with the concentration of hydrofluoric acid at 5% and the cleaning of phosphoric acid. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Cerámica es_ES
dc.subject Äcido Fluorhídrico es_ES
dc.subject Software es_ES
dc.title Efecto de la concentración de ácido fluorhídrico sobre el ángulo de contacto de un adhesivo monocomponente en cerámica de disilicato de litio es_ES
dc.title.alternative Effect of hydrofluoric acid concentration on the contact angle of a single component adhesive in lithium disilicate ceramic es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Cirujano Dentista es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira es_ES
thesis.degree.discipline Estomatología es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#2.05.02 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.14 es_ES
renati.author.dni 71329880
renati.author.dni 70184213
renati.author.dni 76090391
renati.advisor.orcid https://orcid.org/0000-0002-8214-6171 es_ES
renati.advisor.dni 001202335
renati.type http://purl.org/pe-repo/renati/type#trabajoDeInvestigacion es_ES
renati.level http://purl.org/pe-repo/renati/nivel#tituloProfesional es_ES
renati.discipline 911016 es_ES
renati.juror Delgado Cotrina, Leyla Antoinette es_ES
renati.juror Paz Mayuri, Carlos Alberto es_ES
renati.juror Orejuela Ramírez, Francisco José es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas