DSpace Repository

Verificación del desempeño analítico de marcadores bioquímicos de función renal implementados en una plataforma automatizada en el servicio de laboratorio clínico de un hospital en Lima, Perú

Show simple item record

dc.contributor.advisor Fernández Olivera, César Augusto es_ES
dc.contributor.advisor Zavaleta Martínez-Vargas, Alfonso es_ES
dc.contributor.author Duran Dávila, Carmen Alejandra es_ES
dc.contributor.author Mogollón Reyes, Silvana del Rosario es_ES
dc.contributor.author Pulache Mauricio, Álvaro Renzo es_ES
dc.date.accessioned 2022-06-24T22:07:41Z
dc.date.available 2022-06-24T22:07:41Z
dc.date.issued 2021
dc.identifier.other 66891 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/11831
dc.description.abstract Antecedentes: La enfermedad renal crónica afecta la vida de 1 en cada 10 personas a nivel mundial y su incidencia va aumentando, por lo que es necesario que el laboratorio clínico emita resultados confiables para el diagnóstico y seguimiento de pacientes con enfermedades renales. Para lograr esto se debe emplear metodologías analíticas que cumplan las especificaciones técnicas de su fabricante. Objetivos: Verificar el desempeño analítico de las metodologías analíticas de los marcadores de función renal (creatinina, nitrógeno ureico/urea, ácido úrico, proteínas en orina y microalbúmina) implementados en el analizador Dimension RxL Max del Centro Médico Naval, aplicando el protocolo EP 15 A3 del CLSI y comparar el Error total de las metodologías con el Error Total Máximo permitido (ETp) según CLIA y/o Variabilidad Biológica. Materiales y métodos: Se realizó un estudio Descriptivo transversal. Las mediciones de los analitos se realizaron en dos niveles de decisión clínica de control, según la guía del CLSI. Los datos se analizaron en el software estadístico Analyse- it y el programa Microsoft Excel. Resultados: La precisión de repetibilidad y la precisión intralaboratorial verificaron correctamente en todas las metodologías utilizadas. Sin embargo, para veracidad las metodologías de Nitrógeno ureico y Proteínas en orina no verificaron. Solo el error total de ambos métodos superó el ETp según CLIA. Conclusiones: Se puede emplear las metodologías para la detección de creatinina, ácido úrico en sangre y orina y microalbúmina en orina. Se deberá contactar con el fabricante del método de nitrógeno ureico y proteínas en orina para la corrección(es) de error(es) y realizar una nueva verificación del desempeño analítico. es_ES
dc.description.abstract Background: Chronic kidney disease affects the life of 1 in 10 people worldwide and its incidence is increasing. This is why the clinical laboratory must issue reliable results for the diagnosis and follow-up of patients with renal diseases. This is achieved by using analytical methodologies that meet the technical specifications provided by their manufacturer. Objectives: Verify the analytical performance of the markers for renal function (creatinine, urea nitrogen, uric acid, urine proteins and microalbumin) implemented in the Dimension RXL Max automated system of the Naval Medical Center applying the CLSI EP 15 A3 guidelines. Then, compare the Total Errors of the methods with the Maximum allowable error (ETp) by CLIA and Biological Variability. Methods and Materials: A cross-sectional descriptive study was carried out. All runs were made according to EP 15 A3 guidelines for 2 levels of clinical decision reference materials. The data was analyzed using the statistical software Analyse-It and Microsoft Excel. Results: Repeatability and Intralaboratory precision were verified in all methods. However, the methods for urea and urine protein at normal level didn’t verify in trueness. Also, the total errors of both of these methods surpassed the ETp specified by CLIA. Conclusions: The methods for creatinine, uric acid and microalbumin can continue to be used. However, the manufacturer of the urea and urine protein methods should be contacted to correct the errors and then a new analytical performance verification should be made. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Técnicas de Química Analítica es_ES
dc.subject Control de Calidad es_ES
dc.subject Sesgo es_ES
dc.subject Reproducibilidad de Resultados es_ES
dc.subject Pruebas de Función Renal es_ES
dc.title Verificación del desempeño analítico de marcadores bioquímicos de función renal implementados en una plataforma automatizada en el servicio de laboratorio clínico de un hospital en Lima, Perú es_ES
dc.title.alternative Verification of the analytical performance of biochemical markers of renal function implemented in an automated platform in a clinical laboratory of a hospital in Lima, Peru es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Licenciado en Tecnología Médica en la Especialidad de Laboratorio Clínico es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado es_ES
thesis.degree.discipline Tecnología Médica en la Especialidad de Laboratorio Clínico es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#1.04.07 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#2.06.02 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.20 es_ES
renati.author.dni 47210543
renati.author.dni 73692912
renati.author.dni 71336025
renati.advisor.orcid https://orcid.org/0000-0002-8039-9589 es_ES
renati.advisor.dni 41907821
renati.advisor.dni 08425672
renati.type http://purl.org/pe-repo/renati/type#tesis es_ES
renati.level http://purl.org/pe-repo/renati/nivel#tituloProfesional es_ES
renati.discipline 915016 es_ES
renati.juror Figueroa Tataje, Jaime José es_ES
renati.juror Flores Barreto, María Emilia es_ES
renati.juror Siqueros Huaman, David es_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess

Search DSpace


Browse

My Account

Statistics