Universidad Peruana Cayetano Heredia

Efecto de la variación de temperatura sobre los analitos bioquímicos en tubos con gel separador

Mostrar el registro sencillo del ítem

dc.contributor.advisor Sánchez Jacinto, Billy Joel es_ES
dc.contributor.author Chavez Arestegui, Sheyla Allison es_ES
dc.contributor.author Carrillo Huaman, Sania Milusca es_ES
dc.contributor.author Nuñez Rosales, Gladys Estefany es_ES
dc.date.accessioned 2022-10-05T14:23:12Z
dc.date.available 2022-10-05T14:23:12Z
dc.date.issued 2022
dc.identifier.other 200378 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/12251
dc.description.abstract Antecedentes: El tiempo de respuesta (TR) de un resultado contribuye a brindar un diagnóstico temprano y tratamiento oportuno, es por ello que mediante el método baño maría (BM), buscamos reducir el tiempo de la formación del coágulo y con ello acortar el TR en la fase preanalítica. Objetivo: Evaluar el efecto de la variación de temperatura en los analitos bioquímicos en tubos con gel separador. Materiales y métodos: Se realizó un estudio de tipo experimental, transversal, prospectivo. Recolectamos muestras de sangre de 61 voluntarios, donde se comparó el método estándar y método baño maría (BM); se midieron los siguientes analitos: glucosa, colesterol total, colesterol HDL, triglicéridos, deshidrogenasa láctica, fosfatasa alcalina, urea y creatinina. Ambos métodos fueron procesados en un equipo automatizado con la metodología química seca. La concordancia fue evaluada por la prueba de Lin, para el sesgo se utilizó los gráficos de Bland Altman y regresión de Passing Bablok. La significancia clínica se evaluó utilizando la variación biológica de las tablas de Westgard. Resultados: La glucosa y deshidrogenasa láctica presentan significancia estadística (p<0,05), sin embargo, todos los analitos evaluados no presentan relevancia clínica debido que no excede al sesgo deseable de la tabla de Westgard. Conclusiones: El método BM en los 8 analitos bioquímicos no presentó relevancia clínica en los resultados, sin embargo, se necesita de la validación del método para poder implementarse en los laboratorios. es_ES
dc.description.abstract Background: The response time (RT) of a result contributes to providing an early diagnosis and timely treatment, which is why, through the bain-marie (BM) method, we seek to reduce the time of clot formation and thereby shorten the TR in the preanalytical phase. Objective: To evaluate the effect of temperature variation on biochemical analytes in tubes with separating gel. Materials and methods: An experimental, cross-sectional, prospective study was carried out. We collected blood samples from 61 volunteers, where the standard method and the water bath method (BM) were compared; The following analytes were measured: glucose, total cholesterol, HDL cholesterol, triglycerides, lactic dehydrogenase, alkaline phosphatase, urea and creatinine. Both methods were processed in an automated equipment with the dry chemical methodology. The concordance was evaluated by the Lin test, for the bias the Bland Altman graphs and the Passing Bablok regression were extracted. Clinical significance was assessed using the biological variation of the Westgard tables. Results: Glucose and lactic dehydrogenase present statistical significance (p<0.05), however, all the analytes evaluated do not present clinical relevance because they do not exceed the desirable bias of the Westgard table. Conclusions: The BM method in the 8 biochemical analytes did not present clinical evidence in the results, however, the validation of the method is needed to be able to be implemented in the laboratories. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Fase Preanalítica es_ES
dc.subject Temperatura es_ES
dc.subject Pruebas de Laboratorio Clínico es_ES
dc.subject Tubos con Gel Separador es_ES
dc.title Efecto de la variación de temperatura sobre los analitos bioquímicos en tubos con gel separador es_ES
dc.title.alternative Effect of temperature variation on biochemical analytes in serum separator tubes es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Licenciado en Tecnología Médica en la Especialidad de Laboratorio Clínico y Anatomía Patológica es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado es_ES
thesis.degree.discipline Tecnología Médica en la Especialidad de Laboratorio Clínico y Anatomía Patológica es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#1.06.03 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#2.06.02 es_ES
renati.author.dni 71259488
renati.author.dni 73034222
renati.author.dni 76400607
renati.advisor.orcid https://orcid.org/0000-0001-7106-4114 es_ES
renati.advisor.dni 46275162
renati.type http://purl.org/pe-repo/renati/type#tesis es_ES
renati.level http://purl.org/pe-repo/renati/nivel#tituloProfesional es_ES
renati.discipline 915126 es_ES
renati.juror Siqueros Huaman, David es_ES
renati.juror Figueroa Tataje, Jaime José es_ES
renati.juror Flores Barreto, María Emilia es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas