dc.contributor.author |
Cardenas-Pineda, L. |
|
dc.contributor.author |
Jurado-Condori, S. |
|
dc.contributor.author |
Aynar-Martinez, L. |
|
dc.contributor.author |
Ordoñez-Ccora, G. |
|
dc.contributor.author |
Leyva-Yataco, L. |
|
dc.contributor.author |
Cieza Terrones, Michael Javier |
|
dc.contributor.author |
Mantari, A.A. |
|
dc.coverage.spatial |
Huancavelica |
|
dc.date.accessioned |
2023-09-06T20:45:10Z |
|
dc.date.available |
2023-09-06T20:45:10Z |
|
dc.date.issued |
2023 |
|
dc.identifier.uri |
https://hdl.handle.net/20.500.12866/14102 |
|
dc.description.abstract |
This research aims to determine the effect of maternal left lateral decubitus and Fowler positions on electronic fetal monitoring at more than 3600 Masl-Huancavelica, 2021. Method: the research was pre-experimental, prospective, and longitudinal analytical; the level of research is explanatory; normality was evaluated with the Shapiro-Wilk statistician and statistical analysis with the Wilcoxon signed-rank test sample: 35 pregnant women between 32 and 42 weeks. Each one underwent two NST of 20 minutes (LLD and Fowler). Results: the average age was 25 years old and a mean of 37.26 weeks of gestational age; 37.1% were primigravida, 42.9% second gestation and 20% multiple gestations; in the NST in the LLD position, it was found: that 91.4% reactivity, 8.6% non-reactive, there were no pathological, while in the Fowler position: 74.3% presented reactivity, 20.0% non-reactive and 5.7% pathological. The baseline in LLD was 136.06, compared to 139.31 in Fowler. The mean of variability and accelerations was 10.51 and 4.49 in LLD and 9.63 and 3.43 in Fowler; few NSTs were identified with mild variable decelerations of 0.34 and 0.09, and fetal movements were 13.11 and 10.40, respectively. There is a significant difference in the baseline, showing less in LLD (“p” value 0.000). Conclusions: The LLD position shows better results than the non-stress test; a significant difference has been found in the baseline, while the variability, acceleration and movements are similar in both positions with a significance of 0.05. |
en_US |
dc.language.iso |
eng |
|
dc.publisher |
Seventh Sense Research Group |
|
dc.relation.ispartofseries |
International Journal of Engineering Trends and Technology |
|
dc.rights |
info:eu-repo/semantics/restrictedAccess |
|
dc.rights.uri |
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es |
|
dc.subject |
Non-Stress Test (NST) |
en_US |
dc.subject |
Left Lateral Decubitus position (LLD) |
en_US |
dc.subject |
Fowler's position |
en_US |
dc.subject |
Fetal Heart Rate (FHR) |
en_US |
dc.subject.mesh |
Prueba de Esfuerzo |
|
dc.subject.mesh |
Terapia Respiratoria |
|
dc.subject.mesh |
Frecuencia Cardíaca Fetal |
|
dc.title |
Observational Study of Fetal Monitoring in Different Maternal Positions at More Than 3600 Masl Huancavelica, 2021 |
en_US |
dc.type |
info:eu-repo/semantics/article |
|
dc.identifier.doi |
https://doi.org/10.14445/22315381/IJETT-V71I6P207 |
|
dc.relation.issn |
2349-0918 |
|