Mostrar el registro sencillo del ítem
dc.contributor.advisor | Neyra Aguilar, Felix Alexander | es_ES |
dc.contributor.advisor | Sanchez Jacinto, Billy Joel | es_ES |
dc.contributor.author | Huamani Repetto, Javier Alexander | es_ES |
dc.contributor.author | Pretel Espinoza, Heidy Alheli | es_ES |
dc.date.accessioned | 2024-01-26T22:07:39Z | |
dc.date.available | 2024-01-26T22:07:39Z | |
dc.date.issued | 2023 | |
dc.identifier.other | 210203 | es_ES |
dc.identifier.uri | https://hdl.handle.net/20.500.12866/14906 | |
dc.description.abstract | Antecedentes: La radiografía de tórax en neonatos es esencial para evaluación y diagnóstico de afecciones respiratorias. En este proceso, la colimación desempeña un papel fundamental al proteger al neonato de la radiación innecesaria debido a que limita los rayos X al área de interés, evitando la irradiación a otras estructuras. Sin embargo, es frecuente encontrar una mala colimación en esta población, lo que aumenta la exposición a la irradiación innecesaria considerando su mayor radiosensibilidad. Objetivo: Determinar la calidad de colimación en imágenes radiográficas digitales de tórax en neonatos de una clínica privada de Lima-Metropolitana. Métodos y Materiales: El presente estudio es observacional-descriptivo de corte transversal-retrospectivo. Donde se incluyeron 170 imágenes radiográficas digitales de tórax en neonatos almacenados en la memoria interna de un equipo de rayos X rodable digital de la marca Carestream que fueron tomadas durante el año 2021. Resultados: En cuanto a la calidad de colimación, el 41.8% fue mala, el 34.7% regular y solo el 23.5% buena, a su vez, la falta de colimación fue más común en la mandíbula superior, afectando al 70% de los casos. Conclusión: Se necesita mejorar la optimización en términos colimación puesto que solo el 23.5% tuvo buena calidad de colimación, y poner énfasis en la parte superior debido a su alto porcentaje de no colimación en las 3 estructuras correspondientes. | es_ES |
dc.description.abstract | Background: Chest X-rays in neonates are essential for evaluating and diagnosing respiratory conditions. In this process, collimation plays a crucial role in protecting the neonate from unnecessary radiation by limiting X-rays to the area of interest, avoiding irradiation to other structures. However, poor collimation is frequently found in this population, increasing exposure to unnecessary radiation considering their higher radiosensitivity. Objective: To determine the collimation quality in digital chest X-ray images of neonates from a private clinic in Metropolitan Lima. Methods and Materials: This study is an observational-descriptive cross-sectional retrospective analysis. It included 170 digital chest X-ray images of neonates stored in the internal memory of a mobile Carestream digital X-ray machine, taken during the year 2021. Results: Regarding collimation quality, 41.8% were poor, 34.7% were regular, and only 23.5% were good. Lack of collimation was more common in the upper jaw, affecting 70% of the cases. Conclusion: Optimization of collimation needs improvement, given that only 23.5% had good collimation quality. Emphasis should be placed on the upper region due to its high percentage of non-collimation in all three corresponding structures. | es_ES |
dc.format | application/pdf | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad Peruana Cayetano Heredia | es_ES |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | es_ES |
dc.subject | Exposición Inadecuada | es_ES |
dc.subject | Optimización | es_ES |
dc.subject | Calidad de Colimación | es_ES |
dc.subject | Radiografía de Tórax | es_ES |
dc.subject | Neonatos. | es_ES |
dc.title | Calidad de colimación en imágenes radiográficas digitales de tórax en neonatos de una clínica privada de Lima-Metropolitana | es_ES |
dc.title.alternative | Quality of collimation in digital radiographic images of the thorax in neonates in a private clinic in Lima-Metropolitana | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
thesis.degree.name | Licenciado en Tecnología Médica en la Especialidad de Radiología | es_ES |
thesis.degree.grantor | Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado | es_ES |
thesis.degree.discipline | Tecnología Médica en la Especialidad de Radiología | es_ES |
dc.publisher.country | PE | es_ES |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#3.02.03 | es_ES |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#3.02.07 | es_ES |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#3.02.12 | es_ES |
renati.author.dni | 72215343 | |
renati.author.dni | 74733979 | |
renati.advisor.orcid | https://orcid.org/0000-0002-5590-2322 | es_ES |
renati.advisor.orcid | https://orcid.org/0000-0001-7106-4114 | es_ES |
renati.advisor.dni | 43751150 | |
renati.advisor.dni | 46275162 | |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es_ES |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_ES |
renati.discipline | 915076 | es_ES |
renati.juror | Bravo Puente, Guillermo | es_ES |
renati.juror | Maravi Valencia, Carmen Rosa | es_ES |
renati.juror | Ramirez Toscano, Erika Giovana | es_ES |