Determinación de los valores típicos de niveles de referencia de dosis, en estudios tomográficos de cráneo en pacientes adultos, de un hospital nivel III

Show simple item record

dc.contributor.advisor Meca Castro, Edward Artemio es_ES
dc.contributor.advisor Sánchez Jacinto, Billy Joel es_ES
dc.contributor.author Henriquez Cardenas, Rossyvelt Eysaku es_ES
dc.contributor.author Quiñones Gomez, Jerica Jeraldin es_ES
dc.contributor.author Villacorta Ruiz, Francisco Javier es_ES
dc.date.accessioned 2024-05-23T17:29:07Z
dc.date.available 2024-05-23T17:29:07Z
dc.date.issued 2024
dc.identifier.other 210513 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/15432
dc.description.abstract Antecedentes: El crecimiento en el uso de tomografías computarizadas (TC) ha sugerido el aumento de la exposición médica a la radiación ionizante por sus beneficios en la detección de enfermedades como accidente cerebrovascular y traumatismo encéfalo craneano; sin embargo, está vinculado a un mayor riesgo de inducción de cáncer. Por ello, es importante implementar el uso de niveles de referencia de dosis (DRLs) en TC en cada institución que cuente con una sala de rayos X. Objetivo: Determinar los valores típicos de niveles de referencia de dosis en estudios tomográficos de cráneo en pacientes adultos de un Hospital nivel III. Material y método: Estudio analítico y retrospectivo, ya que se utilizó 120 reportes dosimétricos de los estudios tomográficos de cráneo, adquiridos de un tomógrafo marca General Electric (GE), del cual estimamos la mediana de los indicadores de dosis para TC, que son: Índice de dosis en TC por volumen (CTDIvol) y Producto dosis longitud (DLP). De esta manera se determinó los valores típicos de dosis en cada grupo estudiado según sexo, edad e indicación clínica. Resultados: Los valores típicos de DRLs para tomografía de cráneo obtenidos fueron 1216.945 mGy*cm para DLP, y 64.855 mGy para CTDIvol. Conclusiones: Los valores típicos obtenidos de CTDIvol y DLP muestran que la exposición a la radiación fue alta en comparación a otros países. (AU) es_ES
dc.description.abstract Background: The growth in the use of computed tomography (CT) has suggested increased medical exposure to ionizing radiation for its benefits in detecting diseases such as stroke and traumatic brain injury; however, it is linked to an increased risk of cancer induction. Therefore, it is important to implement the use of dose reference levels (DRLs) in CT in each institution that has an X-ray room. Objective: Determine the typical values of dose reference levels in skull tomographic studies in patients adults from a level III Hospital. Material and method: Analytical and retrospective study, since 120 dosimetric reports of skull tomographic studies were used, acquired from a General Electric (GE) tomograph, from which we estimated the median of the dose indicators for CT, which are: dose in CT per volume (CTDIvol) and Dose Length Product (DLP). In this way, the typical dose values were determined in each group studied according to sex, age and clinical indication. Results: The typical values of DRLs for skull tomography obtained were 1216.945 mGy*cm for DLP, and 64.855 mGy for CTDIvol. Conclusions: The obtained typical values of CTDIvol and DLP show that radiation exposure was high compared to other countries. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Dosis de Radiación es_ES
dc.subject Niveles de Referencia es_ES
dc.subject Tomografía Computada es_ES
dc.subject Valor Típico es_ES
dc.title Determinación de los valores típicos de niveles de referencia de dosis, en estudios tomográficos de cráneo en pacientes adultos, de un hospital nivel III es_ES
dc.title.alternative Determination of typical values of reference dose levels, in tomographic studies of the skull in adult patients, of a level III hospital es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Licenciado en Tecnología Médica en la Especialidad de Radiología es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado es_ES
thesis.degree.discipline Tecnología Médica en la Especialidad de Radiología es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.12 es_ES
renati.author.dni 70242766
renati.author.dni 72469933
renati.author.dni 70883531
renati.advisor.orcid https://orcid.org/0000-0002-1226-9299 es_ES
renati.advisor.orcid https://orcid.org/0000-0001-7106-4114 es_ES
renati.advisor.dni 40569815
renati.advisor.dni 46275162
renati.type https://purl.org/pe-repo/renati/type#tesis es_ES
renati.level https://purl.org/pe-repo/renati/level#tituloProfesional es_ES
renati.discipline 915076 es_ES
renati.juror Marquez Pachas, Jose Fernando es_ES
renati.juror Mosquera Vergaray, Natalia Isabel es_ES
renati.juror Tasayco Perez, Evelyn Tatiana es_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess

Search DSpace


Browse

My Account

Statistics