Universidad Peruana Cayetano Heredia

Optimización de la verificación operacional en cromatógrafos de gases 456-GC Scion, analizadores de gas natural: análisis comparativo usando estándares de detectores (método convencional) y tres métodos de análisis (nueva metodología)

Mostrar el registro sencillo del ítem

dc.contributor.advisor Garambel Vilca, Edson Emilio es_ES
dc.contributor.author Guerreros Iñigo, Yony Jhonatan es_ES
dc.date.accessioned 2024-06-13T14:27:05Z
dc.date.available 2024-06-13T14:27:05Z
dc.date.issued 2024
dc.identifier.other 214319 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/15503
dc.description.abstract Durante la verificación operacional del cromatógrafo de gases, los clientes suelen cuestionar si una simple verificación de estándares para los detectores puede garantizar un rendimiento adecuado del cromatógrafo durante sus análisis. No obstante, la verificación operacional de un cromatógrafo de gases involucra una serie de criterios en cromatografía y criterios para la evaluación adecuada de un sistema cromatográfico. Esto incluye el manejo correcto del cromatógrafo de gases, así como manejo del software de control. Por ello, se busca optimizar este proceso de verificación operacional en el cromatógrafo de gases Analizadores. En la empresa Analytical, especializada en servicios de soporte analítico y técnico para equipos de laboratorio, me desempeño como responsable del área de cromatógrafos de gases. Durante la verificación operacional, nuestro principal objetivo es garantizar que el equipo responda de manera óptima en los análisis subsiguientes. No obstante, la efectividad de la verificación tradicional depende en gran medida de los detectores utilizados, lo que determina el tipo de estándar a emplear. Como parte de las mejoras propuestas en Analytical, se plantea una modificación en el procedimiento de verificación operacional del cromatógrafo de gases, en particular para los analizadores. Esta modificación implica utilizar el estándar específico del cliente durante la verificación, lo que aseguraría con mayor precisión que el equipo responde de manera adecuada a las demandas de análisis del cliente. Este cambio en el proceso de verificación se ha evaluado en función de su factibilidad, conveniencia y viabilidad para el cliente, además que se cuenta con lo necesario para realizarla y replicarla. Desde la perspectiva del cliente, esta propuesta supondría un ahorro económico, ya que no sería necesario adquirir un estándar adicional, sino que se utilizaría el mismo estándar empleado en sus análisis regulares. es_ES
dc.description.abstract During the operational verification of a gas chromatograph, customers often question whether a simple standards verification for the detectors can ensure proper chromatograph performance during their analyses. However, the operational verification of a gas chromatograph involves a series of criteria in chromatography and criteria for the proper evaluation of a chromatographic system. This includes the correct handling of the gas chromatograph as well as the control software. Therefore, the goal is to optimize this operational verification process in gas chromatograph analyzers. At Analytical, a company specializing in analytical and technical support services for laboratory equipment, I work as the head of the gas chromatograph department. During operational verification, our main goal is to ensure the equipment responds optimally in subsequent analyses. However, the effectiveness of traditional verification depends largely on the detectors used, which determines the type of standard to employ. As part of proposed improvements at Analytical, we suggest a modification in the operational verification procedure of the gas chromatograph, specifically for analyzers. This modification involves using the client's specific standard during verification, which would more accurately ensure the equipment responds appropriately to the client's analytical demands. This change in the verification process has been evaluated in terms of its feasibility, convenience, and viability for the client, and we have everything necessary to perform and replicate it. From the client's perspective, this proposal would result in cost savings as they would not need to purchase an additional standard; instead, they would use the same standard employed in their regular analyses. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Cromatógrafo de Gases es_ES
dc.subject Verificación Operacional es_ES
dc.subject Análisis de Hidrocarburos es_ES
dc.subject Industria Gas Natural es_ES
dc.subject Cromatógrafo de Gases 456-GC Scion es_ES
dc.title Optimización de la verificación operacional en cromatógrafos de gases 456-GC Scion, analizadores de gas natural: análisis comparativo usando estándares de detectores (método convencional) y tres métodos de análisis (nueva metodología) es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Licenciado en Química es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Ciencias e Ingeniería Alberto Cazorla Talleri es_ES
thesis.degree.discipline Química es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#1.04.02 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#1.04.07 es_ES
renati.author.dni 72747003
renati.advisor.orcid https://orcid.org/0000-0002-7404-3914 es_ES
renati.advisor.dni 44149549
renati.type https://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional es_ES
renati.level https://purl.org/pe-repo/renati/level#tituloProfesional es_ES
renati.discipline 531066 es_ES
renati.juror Guzmán Lezama, Enrique Godofredo es_ES
renati.juror Aviles Pavon, Martha Kelly es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas