DSpace Repository

Consideraciones técnicas en la fase preanalítica para asegurar la determinación de glucosa oxidasa en el diagnóstico en sangre en un centro de salud nivel I-3 durante el año 2023

Show simple item record

dc.contributor.advisor Arias Guzman, Belinda Morayma es_ES
dc.contributor.advisor Bellido Huashuayo, Esther Rosaura es_ES
dc.contributor.author Neira Zevallos, Santos Irene es_ES
dc.contributor.author Saenz Magallanes, Julio Cesar es_ES
dc.date.accessioned 2024-07-04T17:42:56Z
dc.date.available 2024-07-04T17:42:56Z
dc.date.issued 2024
dc.identifier.other 214460 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/15601
dc.description.abstract Introducción: La importancia clínica de controlar los niveles de glucosa en la sangre recae en que permite prevenir la diabetes. En ese sentido, gracias al control de la glucosa, se pueden establecer líneas de prevención en salud. El análisis de glucosa oxidasa cumple con los criterios mínimos establecidos y consta de tres fases: preanalítica, analítica y posanalítica. En estas, se identifican los tipos de errores cometidos para, luego, ser corregidos y mejorar los resultados obtenidos. Objetivo: Describir las consideraciones técnicas en la fase preanalítica para asegurar la determinación de glucosa oxidasa en el diagnóstico en sangre en un centro de salud nivel I-3 durante el año 2023. Descripción del trabajo: Dentro de las consideraciones técnicas, basadas en evidencia, se hace énfasis en la verificación de la recepción de la solicitud de análisis del médico que muchas veces vienen sin un diagnóstico presuntivo. Otra consideración corresponde a las pautas que debe seguir paciente como no ingerir alimentos ricos en grasa y venir en ayuno de ocho horas. En el momento de la toma de muestras, se brinda la información pertinente al paciente acerca del procedimiento que se realizará para evitar los errores preanalíticos. Conclusión: Las consideraciones técnicas para la fase preanalítica en la aplicación del método de glucosa oxidasa en el diagnóstico en sangre debe partir del correcto llenado de la solicitud de análisis, identificación completa del paciente, técnica de punción y transporte de muestra sanguínea. Asimismo, no debe presentar interferencias (hemolisis, ictericia y lipemia), debe haber capacitación continua al personal del laboratorio para mejorar la interacción médico-laboratorio, digitalización/automatización y un adecuado desempeño en el laboratorio. es_ES
dc.description.abstract Introduction: The clinical importance of controlling blood glucose levels occurs in order to prevent diabetes, so the impact of glucose control has greater relevance, since as a result of this; lines of health prevention can be established. The glucose oxidase analysis meets the minimum established criteria, these being the pre-analytical, analytical and post-analytical phases, in which the types of errors made are identified, to later be corrected and improve the results obtained. Objective: Describe the technical considerations in the preanalytical phase to ensure the determination of glucose oxidase in blood diagnosis in a level I-3 Health Center during the year 2023. Job Description: Within the technical considerations, based on evidence, emphasis is placed on verifying receipt of the doctor's analysis request, which often comes without a presumptive diagnosis; Another consideration corresponds to the patient guidelines; do not eat foods rich in fat and come fasting for 8 hours one day before sampling. At the time of sampling, pertinent information is provided to the patient about the procedure that will be performed to avoid preanalytical errors. Conclusion: The technical considerations for the pre-analytical phase in the application of the glucose oxidase method in blood diagnosis must start with correct filling out of the analysis request, complete identification of the patient; the puncture and sample transport technique which must not present interferences (lipemic, insufficient, incorrect or clotted) or hemolysis; and provide continuous training to laboratory staff in improving doctor-laboratory interaction and digitalization/automation for adequate laboratory performance. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Diabetes es_ES
dc.subject Glucosa Oxidasa es_ES
dc.subject Fase Preanalítica es_ES
dc.subject Fase Posanalítica es_ES
dc.subject Fase Analítica es_ES
dc.subject Consideraciones Técnicas es_ES
dc.title Consideraciones técnicas en la fase preanalítica para asegurar la determinación de glucosa oxidasa en el diagnóstico en sangre en un centro de salud nivel I-3 durante el año 2023 es_ES
dc.title.alternative Technical considerations in the pre-analytical phase to ensure the determination of glucose oxidase in the blood diagnosis a level I-3 health center during the year 2023 es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Licenciado en Tecnología Médica en la Especialidad de Laboratorio Clínico y Anatomía Patológica es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado es_ES
thesis.degree.discipline Tecnología Médica en la Especialidad de Laboratorio Clínico y Anatomía Patológica es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#2.06.02 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.18 es_ES
renati.author.dni 21460799
renati.author.dni 21851670
renati.advisor.orcid https://orcid.org/0000-0001-5547-8237 es_ES
renati.advisor.orcid https://orcid.org/0009-0007-9035-8143 es_ES
renati.advisor.dni 10748441
renati.advisor.dni 43532936
renati.type https://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional es_ES
renati.level https://purl.org/pe-repo/renati/level#tituloProfesional es_ES
renati.discipline 915126 es_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess

Search DSpace


Browse

My Account

Statistics