dc.contributor.advisor |
Delgado Cotrina, Leyla Antoinette |
es_ES |
dc.contributor.advisor |
Castañeda Vía, José Alberto |
es_ES |
dc.contributor.author |
Alarcon Cruzado, Ricardo Andre |
es_ES |
dc.date.accessioned |
2024-07-05T21:11:16Z |
|
dc.date.available |
2024-07-05T21:11:16Z |
|
dc.date.issued |
2024 |
|
dc.identifier.other |
207277 |
es_ES |
dc.identifier.uri |
https://hdl.handle.net/20.500.12866/15614 |
|
dc.description.abstract |
Antecedentes: El rendimiento clínico de las resinas compuestas está directamente relacionado con el grado de conversión de monómeros a polímeros después de su fotopolimerización. Es conocido que a bajas temperaturas disminuye el grado de conversión, por lo que es importante encontrar alternativas que optimicen la fotopolimerización. Objetivo: Evaluar el grado de conversión de resinas compuestas fotoactivadas a bajas temperaturas con diferentes protocolos de fotopolimerización. Materiales y métodos: Se confeccionaron 75 especímenes de resina compuesta de 5mm x 2mm. La resina se fotoactivó según 15 protocolos de fotopolimerización. Luego de 24 h, se registraron valores de grado de conversión mediante espectroscopía infrarroja por transformada de Fourier (FTIR). Los datos se analizaron estadísticamente mediante pruebas descriptivos (media y D.E) y pruebas inferenciales (ANOVA/ Duncan) con nivel de confianza del 95%. Resultados: Los valores más bajos de grado de conversión se obtuvieron cuando la resina compuesta se fotoactivó a 0 °C, independientemente de la intensidad y el tiempo. Para el grupo de 10 °C, 1000 mW/cm2 los valores de grado conversión no presentaron diferencias estadísticamente significativas del grupo control en ninguno de los tiempos evaluados (p<0.05). Conclusión: Los valores más bajos de grado de conversión fueron a 0 °C y 10 °C, los cuales fueron más críticos cuando se incrementó la intensidad en cortos períodos de tiempo. A 10 °C, polimerizar en 40 s generó un grado de conversión estable. |
es_ES |
dc.description.abstract |
Background: The clinical performance of composite resins is directly related to the degree of conversion of monomers to polymers after their photopolymerization. It is known that at low temperatures the degree of conversion decreases, so it is important to find alternatives that optimize photopolymerization. Objective: To evaluate the degree of conversion of photoactivated composite resins at low temperatures with different photopolymerization protocols. Materials and methods: Seventy five composite resin specimens were made, 5mm x 2mm. The resin was photoactivated according to 15 photopolymerization protocols. After 24 h, conversion degree values were recorded using Fourier transform infrared spectroscopy (FTIR). The data were statistically analyzed using descriptive tests (mean and S.D.) and inferential tests (ANOVA/Duncan) with a 95% confidence level. Results: The lowest conversion degree values were obtained when the composite resin was photoactivated at a temperature of 0 °C, regardless of intensity and time. For the 10 °C, 1000 mW/cm2 group, the conversion degree values did not show statistically significant differences from the control group at any of the evaluated times (p<0.05). Conclusion: The lowest values of degree of conversion were at temperatures 0 °C and 10 °C, which were more critical when the intensity was increased in short periods of time. At a temperature of 10 °C, polymerizing in 40s generated a stable degree of conversion. |
es_ES |
dc.format |
application/pdf |
es_ES |
dc.language.iso |
spa |
es_ES |
dc.publisher |
Universidad Peruana Cayetano Heredia |
es_ES |
dc.rights |
info:eu-repo/semantics/openAccess |
es_ES |
dc.rights.uri |
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es |
es_ES |
dc.subject |
Temperatura |
es_ES |
dc.subject |
Grado de Conversión |
es_ES |
dc.subject |
Fotopolimerización |
es_ES |
dc.subject |
Resinas Compuestas |
es_ES |
dc.title |
Evaluación del grado de conversión de una resina compuesta fotoactivada a bajas temperaturas en diferentes protocolos de polimerización |
es_ES |
dc.type |
info:eu-repo/semantics/masterThesis |
es_ES |
thesis.degree.name |
Maestro en Estomatología |
es_ES |
thesis.degree.grantor |
Universidad Peruana Cayetano Heredia. Escuela de Posgrado Víctor Alzamora Castro |
es_ES |
thesis.degree.discipline |
Estomatología |
es_ES |
dc.publisher.country |
PE |
es_ES |
dc.subject.ocde |
http://purl.org/pe-repo/ocde/ford#1.04.04 |
es_ES |
dc.subject.ocde |
http://purl.org/pe-repo/ocde/ford#3.02.14 |
es_ES |
renati.author.dni |
73008737 |
|
renati.advisor.orcid |
https://orcid.org/0000-0002-3027-178X |
es_ES |
renati.advisor.orcid |
https://orcid.org/0000-0002-5199-475X |
es_ES |
renati.advisor.dni |
10193841 |
|
renati.advisor.dni |
71821060 |
|
renati.type |
https://purl.org/pe-repo/renati/type#tesis |
es_ES |
renati.level |
https://purl.org/pe-repo/renati/level#maestro |
es_ES |
renati.discipline |
911057 |
es_ES |
renati.juror |
Tay Chu Jon, Lidia Yileng |
es_ES |
renati.juror |
Chavez Alayo, Pablo Armando |
es_ES |
renati.juror |
Cuadros Sanchez, Johanna Lizbeth |
es_ES |