dc.description.abstract |
Introducción: Las imágenes tomográficas son importantes para el diagnóstico médico, pero la falta de acceso a programas de procesamiento y almacenamiento tiene un impacto negativo en la calidad del tratamiento en centros de salud. RadiAnt® ofrece una solución al brindar acceso completo y simplificado a las imágenes, mejorando la precisión del diagnóstico y agilizando la atención al paciente. Objetivos: Identificar las consideraciones técnicas para la adecuada aplicación del programa RadiAnt® que contribuye al diagnóstico en tomografía en un centro de salud durante un periodo de seis meses en los meses de junio a noviembre de 2023 (Comas-Lima, Perú 2023). Descripción del trabajo: La implementación del programa RadiAnt® se basa en la ausencia del sistema DICOM/ RIS/ SIS/ PACS para el envío, reconstrucción y verificación de imágenes. Al ser un programa gratuito, RadiAnt® ofrece una opción para el almacenamiento, el procesamiento y la gestión de imagen. Sin embargo, es importante tener en cuenta tres componentes para su uso: requerimientos mínimos, ventajas y desventajas, y pasos para el procedimiento; reduciendo las limitaciones de las placas radiográficas. Conclusión: La implementación del programa RadiAnt® en el diagnóstico tomográfico se basa en el aprendizaje adecuado del personal y tecnólogo médico, así como en la compatibilidad de las imágenes, lo cual posibilita una solución rápida y accesible para los centros de salud de diversos niveles principalmente medio-bajo. |
es_ES |
dc.description.abstract |
Introduction: Tomographic images are important for medical diagnosis, the lack of access to processing and storage programs has a negative impact on the quality of treatment in health centers. RadiAnt® offers a solution by providing complete and simplified access to images, improving diagnostic accuracy and streamlining patient care. Objectives: Identify the technical considerations for the proper application of the RadiAnt® program that contributes to tomography diagnosis in a health center during a period of 6 months in the months of June to November 2023 (Comas- Lima, Peru 2023). Job Description: The implementation of the RadiAnt® program is based on the absence of the DICOM/ RIS/ SIS/ PACS system for sending, reconstruction and verification of images. Being a free program, RadiAnt® offers an option for image storage, processing and management. However, it is important to take into account three aspects for its use: knowing the software, manual guide to install and compatibility with tomographic equipment; reducing the limitations of radiographic plates. Conclusion: The implementation of the RadiAnt® program in tomographic diagnosis is based on the adequate learning of the medical staff and technologist, as well as the compatibility of the images, which enables a quick and accessible solution for health centers of various levels, mainly medium-low. |
es_ES |
dc.format |
application/pdf |
es_ES |
dc.language.iso |
spa |
es_ES |
dc.publisher |
Universidad Peruana Cayetano Heredia |
es_ES |
dc.rights |
info:eu-repo/semantics/openAccess |
es_ES |
dc.rights.uri |
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es |
es_ES |
dc.subject |
Radiología |
es_ES |
dc.subject |
RadiAnt |
es_ES |
dc.subject |
Tomografía |
es_ES |
dc.title |
Consideraciones técnicas para la adecuada aplicación del programa RadiAnt® que contribuye al diagnóstico en tomografía en un centro de salud durante un periodo de 6 meses (Comas- Lima, Perú 2023) |
es_ES |
dc.title.alternative |
Technical considerations for the proper application of the RadiAnt® program that contributes to diagnosis in tomography in a health center during a period of 6 months (Comas- Lima, Peru 2023) |
es_ES |
dc.type |
info:eu-repo/semantics/bachelorThesis |
es_ES |
thesis.degree.name |
Licenciado en Tecnología Médica en la Especialidad de Radiología |
es_ES |
thesis.degree.grantor |
Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado |
es_ES |
thesis.degree.discipline |
Tecnología Médica en la Especialidad de Radiología |
es_ES |
dc.publisher.country |
PE |
es_ES |
dc.subject.ocde |
http://purl.org/pe-repo/ocde/ford#3.02.12 |
es_ES |
renati.author.dni |
73200896 |
|
renati.advisor.orcid |
https://orcid.org/0009-0004-3846-6751 |
es_ES |
renati.advisor.orcid |
https://orcid.org/0000-0002-8462-3218 |
es_ES |
renati.advisor.dni |
09218831 |
|
renati.advisor.dni |
70214397 |
|
renati.type |
https://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional |
es_ES |
renati.level |
https://purl.org/pe-repo/renati/level#tituloProfesional |
es_ES |
renati.discipline |
915076 |
es_ES |