dc.contributor.advisor |
Mosquera Vergaray, Natalia Isabel |
es_ES |
dc.contributor.advisor |
Huayanay Espinoza, Carlos Andres |
es_ES |
dc.contributor.author |
Huancas Diaz, Carlos Yair |
es_ES |
dc.contributor.author |
Tasayco Pérez, Evelyn Tatiana |
es_ES |
dc.date.accessioned |
2024-07-16T13:58:28Z |
|
dc.date.available |
2024-07-16T13:58:28Z |
|
dc.date.issued |
2024 |
|
dc.identifier.other |
214506 |
es_ES |
dc.identifier.uri |
https://hdl.handle.net/20.500.12866/15661 |
|
dc.description.abstract |
ntroducción: La Urotomografía Computarizada (URO-TC) es el examen de primera línea para evaluar la funcionabilidad del sistema urinario. Esta puede generar sobreexposición en los pacientes. Existen nuevas técnicas como la de SPLIT BOLUS que nos ayuda a disminuir la exposición a la radiación del paciente, ya que reducimos el estudio a 2 adquisiciones, a diferencia de la técnica convencional donde se hacen 5 adquisiciones por estudio. Objetivo: Describir las consideraciones técnicas para una adecuada adquisición de imágenes de urotomografía con medio de contraste y energía dual en un centro de salud privado durante el año 2023. Descripción del trabajo: Según la evidencia revisada, las consideraciones técnicas para una adecuada adquisición de imágenes en URO-TC deben ser: 1. Preparación del paciente: ayuno previo al estudio, exámenes de laboratorio, etc. 2. Adquisición de las imágenes: se usarán parámetros técnicos ya establecidos, como el uso de la doble energía y la inyección de contraste yodado mediante la técnica SPLIT BOLUS 3. Postproceso de imágenes usando Syngo.via by Siemens Healthcare. Conclusión: La adecuada aplicación de la técnica de SPLIT BOLUS combinada con el uso de energía dual, usando los aspectos previamente mencionados, reduce la exposición a la radiación del paciente y la reducción del tiempo del estudio además de entregarnos imágenes que conservan calidad diagnóstica. |
es_ES |
dc.description.abstract |
Introduction: Computed Urotomography (URO-TC) is the first-line test to assess the functionability of the urinary system. It can lead to overexposure to radiation in patients. There are new techniques such as SPLIT BOLUS that help us to reduce the radiation exposure time for patients, since we reduce the study to 2 image acquisitions, compared to the conventional technique where 5 acquisitions are made per study. Objectives: Describe the technical aspects to implement a protocol for an appropriate acquisition of urotomography images with contrast medium and dual energy in a private health center during the year 2023. Description of the study: According to the reviewed evidence, the technical aspects for an appropriate acquisition of images in CTU should be: 1. Patient preparation, fasting prior to the study, laboratory tests, etc. 2. Image acquisition, already established technical parameters will be used, such as the use of dual energy and contrast injection using the SPLIT BOLUS technique 3. Image post-processing, using Syngo.via by Siemens Healthcare. Conclusion: The proper application of the SPLIT BOLUS technique combined with the use of dual energy, using the previously mentioned aspects, reduces patient's radiation exposure and the study time as well as giving images that preserve diagnostic quality. |
es_ES |
dc.format |
application/pdf |
es_ES |
dc.language.iso |
spa |
es_ES |
dc.publisher |
Universidad Peruana Cayetano Heredia |
es_ES |
dc.rights |
info:eu-repo/semantics/openAccess |
es_ES |
dc.rights.uri |
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es |
es_ES |
dc.subject |
Doble Energía |
es_ES |
dc.subject |
Split Bolus |
es_ES |
dc.subject |
Medio de Contraste |
es_ES |
dc.subject |
Urografía |
es_ES |
dc.subject |
Tomografía |
es_ES |
dc.title |
Consideraciones técnicas para la adquisición de imágenes de uro-tomografía con medio de contraste y energía dual, utilizado en un centro privado durante el periodo de 2023 |
es_ES |
dc.title.alternative |
Technical considerations for the acquisition of uro-tomography images with contrast medium and dual energy, used in a private center during the period of 2023 |
es_ES |
dc.type |
info:eu-repo/semantics/bachelorThesis |
es_ES |
thesis.degree.name |
Licenciado en Tecnología Médica en la Especialidad de Radiología |
es_ES |
thesis.degree.grantor |
Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado |
es_ES |
thesis.degree.discipline |
Tecnología Médica en la Especialidad de Radiología |
es_ES |
dc.publisher.country |
PE |
es_ES |
dc.subject.ocde |
http://purl.org/pe-repo/ocde/ford#3.01.09 |
es_ES |
dc.subject.ocde |
http://purl.org/pe-repo/ocde/ford#3.02.12 |
es_ES |
dc.subject.ocde |
http://purl.org/pe-repo/ocde/ford#3.02.20 |
es_ES |
renati.author.dni |
74550927 |
|
renati.author.dni |
72314468 |
|
renati.advisor.orcid |
https://orcid.org/0000-0003-1372-4449 |
es_ES |
renati.advisor.orcid |
https://orcid.org/0000-0002-8462-3218 |
es_ES |
renati.advisor.dni |
09396333 |
|
renati.advisor.dni |
70214397 |
|
renati.type |
https://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional |
es_ES |
renati.level |
https://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad |
es_ES |
renati.discipline |
915076 |
es_ES |