Universidad Peruana Cayetano Heredia

Precisión diagnóstica de la ecografía pulmonar en comparación con la radiografía de tórax para el diagnóstico de neumonía adquirida en la comunidad en adultos: una revisión de alcance (scoping review)

Mostrar el registro sencillo del ítem

dc.contributor.advisor Luis Miranda, Cecilia es_ES
dc.contributor.author Cayetano Alvarez, Diego Alexander es_ES
dc.contributor.author La Torre Lopez, Gian Franco Alexander es_ES
dc.contributor.author Yanasupo Rondinel, Jahayra Arlyn Milagros es_ES
dc.date.accessioned 2025-05-05T20:13:22Z
dc.date.available 2025-05-05T20:13:22Z
dc.date.issued 2025
dc.identifier.other 214850 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/17022
dc.description.abstract Introducción: La neumonía adquirida en la comunidad (NAC) es una infección aguda del parénquima pulmonar que se presenta fuera del entorno hospitalario. Para su diagnóstico, según una Guía práctica clínica de Perú recomiendan la radiografía de tórax como método estándar ante la sospecha de NAC en pacientes adultos. Sin embargo, aunque la radiografía de tórax se considera el examen de primera línea en este contexto, la ecografía pulmonar ha emergido como una alternativa favorable, debido a su menor costo y a la ventaja de no requerir radiación ionizante Objetivo: Mapear la precisión diagnóstica de la ecografía pulmonar en comparación a la radiografía de tórax en el diagnóstico de la neumonía adquirida en la comunidad en adultos a través de una revisión exploratoria de artículos (Scoping review). Metodología: Se llevó a cabo una revisión de alcance, donde se realizó una búsqueda en bases de datos académicas como PubMed, Embase y Google Académico como fuente de literatura gris. Tras aplicar los criterios de inclusión, se seleccionaron 23 artículos siguiendo las etapas del diagrama de flujo PRISMA. Los resultados se analizaron de forma descriptiva y mediante frecuencias, presentándolos en tablas que facilitaron su interpretación. Resultados: La precisión diagnóstica se evaluó considerando el diseño del estudio, el tamaño muestral y la temporalidad. La EP en revisiones sistemáticas y metaanálisis, mostró una sensibilidad promedio de 94,3% y una especificidad de 89,3%. En estudios con tamaños muestrales grandes (5000-7000 pacientes), la EP mostró valores altos de VPP y VPN, con promedios de 93% y 92%, respectivamente. En temporalidad, en el período 2020-2024, la EP tuvo una sensibilidad de 87,13% y una especificidad 87,99%. - Conclusiones: La ecografía pulmonar es un método diagnóstico con una alta sensibilidad y especificidad, además de VPP y VPN para la detección de NAC en pacientes adultos comparable a la radiografía de tórax, en situaciones donde no es concluyente el diagnóstico de la NAC, sería una alternativa recomendable utilizar otro método diagnóstico como es la tomografía computarizada. es_ES
dc.description.abstract Introduction: Community-acquired pneumonia (CAP) is an acute infection of the pulmonary parenchyma that occurs outside the hospital setting. For its diagnosis, international guidelines according to a Clinical Practice Guide from Peru recommend chest X-ray as a routine examination in patients with suspected CAP in adult patients with pneumonia. However, although chest radiography is considered the first-line diagnostic tool in this context, lung ultrasound has emerged as a favorable alternative due to its lower cost and the advantage of not requiring ionizing radiation.Objective: To map the diagnostic accuracy of lung ultrasound compared to chest radiography in the diagnosis of community-acquired pneumonia in adults through a scoping review of the literature.Methodology: A scoping review was conducted, where searches were performed in academic databases such as PubMed, Embase, and Google Scholar as a source of grey literature. After applying the inclusion criteria, 23 articles were selected following the PRISMA flow diagram stages. The results were analyzed descriptively and through frequencies, presenting them in tables to facilitate interpretation.Results: Diagnostic accuracy was assessed considering study design, sample size, and temporality. In systematic reviews and meta-analyses, the EP showed an average sensitivity of 94.3% and a specificity of 89.3%. In studies with large sample sizes (5000-7000 patients), the EP showed high PPV and NPV values, with averages of 93% and 92%, respectively. In temporality, in the period 2020-2024, the EP had a sensitivity of 87.13% and a specificity of 87.99%.Conclusions: Lung ultrasound is a diagnostic method with high sensitivity and specificity, in addition to PPV and NPV for the detection of CAP in adult patients comparable to chest X-ray; in situations where the diagnosis of CAP is not conclusive, it would be a recommended alternative to use another diagnostic method such as computed tomography. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Radiografía de Tórax es_ES
dc.subject Ecografía Pulmonar es_ES
dc.subject Sensibilidad es_ES
dc.subject Especificidad es_ES
dc.title Precisión diagnóstica de la ecografía pulmonar en comparación con la radiografía de tórax para el diagnóstico de neumonía adquirida en la comunidad en adultos: una revisión de alcance (scoping review) es_ES
dc.title.alternative Diagnostic accuracy of lung ultrasound compared with chest radiography for the diagnosis of community-acquired pneumonia in adults: a scoping review es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Licenciado en Tecnología Médica en la Especialidad de Radiología es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado es_ES
thesis.degree.discipline Tecnología Médica en la Especialidad de Radiología es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.07 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.12 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.03.08 es_ES
renati.author.dni 77919969
renati.author.dni 74062009
renati.author.dni 70928119
renati.advisor.orcid https://orcid.org/0009-0003-4631-2210 es_ES
renati.advisor.dni 07168077
renati.type https://purl.org/pe-repo/renati/type#tesis es_ES
renati.level https://purl.org/pe-repo/renati/level#tituloProfesional es_ES
renati.discipline 915076 es_ES
renati.juror Bravo Puente, Guillermo es_ES
renati.juror Acosta Rengifo, Nora del Pilar es_ES
renati.juror Neyra Aguilar, Felix Alexander es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas