Universidad Peruana Cayetano Heredia

Automated microscopy for routine malaria diagnosis: a field comparison on Giemsa-stained blood films in Peru

Mostrar el registro sencillo del ítem

dc.contributor.author Torres Fajardo, Katherine Jessica
dc.contributor.author Bachman, Christine M.
dc.contributor.author Delahunt, Charles B.
dc.contributor.author Alarcon Baldeon, Jhonatan
dc.contributor.author Alava, Freddy
dc.contributor.author Gamboa Vilela, Dionicia Baziliza
dc.contributor.author Proux, Stephane
dc.contributor.author Mehanian, Courosh
dc.contributor.author McGuire, Shawn K.
dc.contributor.author Thompson, Clay M.
dc.contributor.author Ostbye, Travis
dc.contributor.author Hu, Liming
dc.contributor.author Jaiswal, Mayoore S.
dc.contributor.author Hunt, Victoria M.
dc.contributor.author Bell, David
dc.date.accessioned 2018-11-30T02:09:30Z
dc.date.available 2018-11-30T02:09:30Z
dc.date.issued 2018
dc.identifier.uri https://hdl.handle.net/20.500.12866/4010
dc.description.abstract BACKGROUND: Microscopic examination of Giemsa-stained blood films remains a major form of diagnosis in malaria case management, and is a reference standard for research. However, as with other visualization-based diagnoses, accuracy depends on individual technician performance, making standardization difficult and reliability poor. Automated image recognition based on machine-learning, utilizing convolutional neural networks, offers potential to overcome these drawbacks. A prototype digital microscope device employing an algorithm based on machine-learning, the Autoscope, was assessed for its potential in malaria microscopy. Autoscope was tested in the Iquitos region of Peru in 2016 at two peripheral health facilities, with routine microscopy and PCR as reference standards. The main outcome measures include sensitivity and specificity of diagnosis of malaria from Giemsa-stained blood films, using PCR as reference. METHODS: A cross-sectional, observational trial was conducted at two peripheral primary health facilities in Peru. 700 participants were enrolled with the criteria: (1) age between 5 and 75 years, (2) history of fever in the last 3 days or elevated temperature on admission, (3) informed consent. The main outcome measures included sensitivity and specificity of diagnosis of malaria from Giemsa-stained blood films, using PCR as reference. RESULTS: At the San Juan clinic, sensitivity of Autoscope for diagnosing malaria was 72% (95% CI 64-80%), and specificity was 85% (95% CI 79-90%). Microscopy performance was similar to Autoscope, with sensitivity 68% (95% CI 59-76%) and specificity 100% (95% CI 98-100%). At San Juan, 85% of prepared slides had a minimum of 600 WBCs imaged, thus meeting Autoscope's design assumptions. At the second clinic, Santa Clara, the sensitivity of Autoscope was 52% (95% CI 44-60%) and specificity was 70% (95% CI 64-76%). Microscopy performance at Santa Clara was 42% (95% CI 34-51) and specificity was 97% (95% CI 94-99). Only 39% of slides from Santa Clara met Autoscope's design assumptions regarding WBCs imaged. CONCLUSIONS: Autoscope's diagnostic performance was on par with routine microscopy when slides had adequate blood volume to meet its design assumptions, as represented by results from the San Juan clinic. Autoscope's diagnostic performance was poorer than routine microscopy on slides from the Santa Clara clinic, which generated slides with lower blood volumes. Results of the study reflect both the potential for artificial intelligence to perform tasks currently conducted by highly-trained experts, and the challenges of replicating the adaptiveness of human thought processes. en_US
dc.language.iso eng
dc.publisher BioMed Central
dc.relation.ispartofseries Malaria Journal
dc.rights info:eu-repo/semantics/restrictedAccess
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subject Artificial intelligence en_US
dc.subject Convolutional neural networks en_US
dc.subject Digital microscopy en_US
dc.subject Malaria en_US
dc.subject Microscopy en_US
dc.title Automated microscopy for routine malaria diagnosis: a field comparison on Giemsa-stained blood films in Peru en_US
dc.type info:eu-repo/semantics/article
dc.identifier.doi https://doi.org/10.1186/s12936-018-2493-0
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#3.03.07
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#3.03.08
dc.relation.issn 1475-2875


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/restrictedAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/restrictedAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas