Universidad Peruana Cayetano Heredia

Diagnostic accuracy of a charge-coupled device and a photostimulable phosphor plate in detection of non-cavitated proximal caries

Mostrar el registro sencillo del ítem

dc.contributor.author Trevejo-Bocanegra, A.P.
dc.contributor.author Hidalgo, A.
dc.contributor.author Beltrán Silva, Jorge Arturo
dc.date.accessioned 2018-11-30T23:41:32Z
dc.date.available 2018-11-30T23:41:32Z
dc.date.issued 2018
dc.identifier.uri https://hdl.handle.net/20.500.12866/4229
dc.description.abstract Objective: The aim of this study was to compare the diagnostic accuracy of two direct digital radiography systems: the charge-coupled device (CCD) XIOS XG Sirona® and the photostimulable storage phosphor (PSP) VistaScan DürrDental®, in the detection of non-cavitated proximal caries lesions. Materials and methods: in this experimental and cross-sectional study 112 proximal surfaces from 27 molars and 31 premolars with or without proximal caries lesions were evaluated and randomly allocated in a study unit. Bitewing radiographs were acquired with a CCD XIOS XG and with the PSP VistaScan. A single X-ray unit was used for both systems. Radiographic images were assessed independently by two calibrated radiologists. Histological evaluation on a stereomicroscope was used as gold standard. Results: Sensitivity values were found to be 0.35 for CCD and 0.31 for PSP. Specificity values were found to be similar for both systems (0.867). Az values showed a low diagnostic accuracy for both sensors: 0.61 for CCD and 0.59 for PSP, no statistical difference was found between these two values (p=0.78). Conclusion: Both digital radiology systems have a high diagnostic accuracy to detect sound surfaces but low diagnostic accuracy to detect proximal carious lesions. en_US
dc.language.iso eng
dc.publisher Facultad de Odontología. Universidad de Concepción
dc.relation.ispartofseries Journal of Oral Research
dc.rights info:eu-repo/semantics/restrictedAccess
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subject Dental caries en_US
dc.subject Dental radiography en_US
dc.subject Sensitivity en_US
dc.subject Specificity en_US
dc.title Diagnostic accuracy of a charge-coupled device and a photostimulable phosphor plate in detection of non-cavitated proximal caries en_US
dc.type info:eu-repo/semantics/article
dc.identifier.doi https://doi.org/10.17126/joralres.2018.017
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#3.02.14
dc.relation.issn 0719-2479


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/restrictedAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/restrictedAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas