DSpace Repository

Micropulse Trabeculoplasty in Open Angle Glaucoma

Show simple item record

dc.contributor.author Valera-Cornejo, Diego Alejandro
dc.contributor.author Loayza-Gamboa, Waldo
dc.contributor.author Herrera-Quiroz, Julio
dc.contributor.author Alvarado-Vlllacorta, Rosa
dc.contributor.author Cordova-Crisanto, Luis
dc.contributor.author Valderrama-Albino, Vanessa
dc.contributor.author Davalos, Nahuel P.
dc.date.accessioned 2019-03-05T15:23:24Z
dc.date.available 2019-03-05T15:23:24Z
dc.date.issued 2018
dc.identifier.uri https://hdl.handle.net/20.500.12866/5861
dc.description.abstract Background: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). Materials and Methods: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in Lima Peru. We used a 532 nm frequency doubled Nd: YAG laser to 360 degrees of the trabecular meshwork with a power of 1000 mW, 15% of the duty cycle, and 300 ms of exposure. The IOP was measured at baseline and at 1 day, 1 week, 3 months, and 6 months post-treatment and were followed up for one last control. Results: The mean baseline IOP was 15.6 mmHg and in the last control was 12.8 mmHg, mean follow-up time of 19 months (+/-10 standard deviation [SD]). The mean reduction of IOP in the 1(st) day was 1.6 mmHg (+/-2.6 SD) and 1.2 mmHg (+/-3.3 SD) in the last follow-up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction >20%. No statistical significant difference in relation to demographic characteristics of the patients. The greatest reduction was achieved in the 1(st) day with a median of 2.00 (P < 0.001). A tendency to achieve a higher reduction of IOP in patients with higher baseline IOP was found but was not statistically significant. No adverse reactions occurred. Conclusions: MLT slightly reduced the IOP in a few patients with uncontrolled OAG for a very short time and may not be suitable for these patients. en_US
dc.language.iso eng
dc.publisher Medknow Publications
dc.relation.ispartofseries Advanced Biomedical Research
dc.rights info:eu-repo/semantics/restrictedAccess
dc.subject Diode laser en_US
dc.subject micropulse en_US
dc.subject open angle glaucoma en_US
dc.subject subthreshold en_US
dc.subject trabeculoplasty en_US
dc.title Micropulse Trabeculoplasty in Open Angle Glaucoma en_US
dc.type info:eu-repo/semantics/article
dc.identifier.doi https://doi.org/10.4103/abr.abr_203_17
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#3.01.00
dc.relation.issn 2277-9175


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics