Universidad Peruana Cayetano Heredia

Micropulse Trabeculoplasty in Open Angle Glaucoma

Mostrar el registro sencillo del ítem

dc.contributor.author Valera-Cornejo, Diego Alejandro
dc.contributor.author Loayza-Gamboa, Waldo
dc.contributor.author Herrera-Quiroz, Julio
dc.contributor.author Alvarado-Vlllacorta, Rosa
dc.contributor.author Cordova-Crisanto, Luis
dc.contributor.author Valderrama-Albino, Vanessa
dc.contributor.author Davalos, Nahuel P.
dc.date.accessioned 2019-03-05T15:23:24Z
dc.date.available 2019-03-05T15:23:24Z
dc.date.issued 2018
dc.identifier.uri https://hdl.handle.net/20.500.12866/5861
dc.description.abstract Background: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). Materials and Methods: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in Lima Peru. We used a 532 nm frequency doubled Nd: YAG laser to 360 degrees of the trabecular meshwork with a power of 1000 mW, 15% of the duty cycle, and 300 ms of exposure. The IOP was measured at baseline and at 1 day, 1 week, 3 months, and 6 months post-treatment and were followed up for one last control. Results: The mean baseline IOP was 15.6 mmHg and in the last control was 12.8 mmHg, mean follow-up time of 19 months (+/-10 standard deviation [SD]). The mean reduction of IOP in the 1(st) day was 1.6 mmHg (+/-2.6 SD) and 1.2 mmHg (+/-3.3 SD) in the last follow-up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction >20%. No statistical significant difference in relation to demographic characteristics of the patients. The greatest reduction was achieved in the 1(st) day with a median of 2.00 (P < 0.001). A tendency to achieve a higher reduction of IOP in patients with higher baseline IOP was found but was not statistically significant. No adverse reactions occurred. Conclusions: MLT slightly reduced the IOP in a few patients with uncontrolled OAG for a very short time and may not be suitable for these patients. en_US
dc.language.iso eng
dc.publisher Medknow Publications
dc.relation.ispartofseries Advanced Biomedical Research
dc.rights info:eu-repo/semantics/restrictedAccess
dc.subject Diode laser en_US
dc.subject micropulse en_US
dc.subject open angle glaucoma en_US
dc.subject subthreshold en_US
dc.subject trabeculoplasty en_US
dc.title Micropulse Trabeculoplasty in Open Angle Glaucoma en_US
dc.type info:eu-repo/semantics/article
dc.identifier.doi https://doi.org/10.4103/abr.abr_203_17
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#3.01.00
dc.relation.issn 2277-9175


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas