Universidad Peruana Cayetano Heredia

Assessment of Two Diabetes Point-of-care Analyzers Measuring Hemoglobin A1c in the Peruvian Amazon

Mostrar el registro sencillo del ítem

dc.contributor.author Saxton, Anthony T.
dc.contributor.author Miranda, J. Jaime
dc.contributor.author Ortiz, Ernesto J.
dc.contributor.author Pan, William
dc.date.accessioned 2019-03-05T15:23:25Z
dc.date.available 2019-03-05T15:23:25Z
dc.date.issued 2018
dc.identifier.uri https://hdl.handle.net/20.500.12866/5868
dc.description.abstract BACKGROUND: With an estimated 174 million undiagnosed cases of diabetes mellitus worldwide and 80% of them occurring in low- and middle-income countries an effective point-of-care diagnostic tool is key to fighting this global epidemic. Glycated hemoglobin has become a reliable biomarker for the diagnosis and prognosis of diabetes. OBJECTIVE: We assessed two point-of-care (POC) analyzers in multi-ethnic communities of the Amazon Rainforest in Peru where laboratory-based glycated hemoglobin (HbA1c) testing is not available. METHODS: 203 venous blood samples were tested for HbA1c by Afinion and DCA Vantage analyzers as well as a Premier Hb9210 high-performance liquid chromatography (HPLC) method as the reference standard. The coefficient of variation (CV) of each device was calculated to assess assay imprecision. Bland-Altman plots were used to assess bias. Ambient temperature, humidity, and barometric pressure were also evaluated for their effect on HbA1c results using multivariate regression. FINDINGS: There was a wide range of HbA1c for participants based on the HPLC test: 4.4-9.0% (25-75 mmol/mol). The CV for the Afinion was 1.75%, and 4.01% for Vantage. The Afinion generated higher HbA1c results than the HPLC (mean difference = +0.56% [+6 mmol/mol]; p < 0.001), as did the DCA Vantage (mean difference = +0.32% [4 mmol/mol] p < 0.001). Temperature and humidity were not related to HbA1c; however, barometric pressure was associated with HPLC HbA1c results for the Afinion. CONCLUSIONS: Imprecision and bias were not low enough to recommend either POC analyzer for HbA1c determinations in this setting. en_US
dc.language.iso eng
dc.publisher Levy Library Press
dc.relation.ispartofseries Annals of Global Health
dc.rights info:eu-repo/semantics/restrictedAccess
dc.subject Diabetes en_US
dc.subject Hemoglobin A1c en_US
dc.subject Peruvian Amazon en_US
dc.title Assessment of Two Diabetes Point-of-care Analyzers Measuring Hemoglobin A1c in the Peruvian Amazon en_US
dc.type info:eu-repo/semantics/article
dc.identifier.doi https://doi.org/10.29024/aogh.2368
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#3.02.00
dc.relation.issn 2214-9996


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas