DSpace Repository

Dual rapid test for HIV and syphilis: A laboratory evaluation of the diagnostic accuracy of the Standard Q HIV/Syphilis Combo Test

Show simple item record

dc.contributor.author Bristow, Claire C.
dc.contributor.author Vargas Rivera, Silver Keith
dc.contributor.author Ramos Cordova, Lourdes B.
dc.contributor.author Qquellon Palacios, Luz Jazmín
dc.contributor.author Konda, Kelika A.
dc.contributor.author Klausner, Jeffrey D.
dc.date.accessioned 2019-03-05T15:25:03Z
dc.date.available 2019-03-05T15:25:03Z
dc.date.issued 2018
dc.identifier.uri https://hdl.handle.net/20.500.12866/5937
dc.description.abstract We evaluated the Standard Q HIV/Syphilis Combo Test (SD Biosensor, South Korea), a dual rapid test using stored sera (N = 400) in a laboratory setting in Lima, Peru. The sensitivity and specificity for HIV antibody detection was 100.0% (95% CI: 98.2–100.0%) and 99.5% (95% CI: 97.2–100.0%), respectively. For treponemal antibody detection the sensitivity and specificity was 97.5% (95%CI:94.3–99.2%) and 100.0% (95%CI:98.2–100.0%), respectively. en_US
dc.language.iso eng
dc.publisher Elsevier
dc.relation.ispartofseries Diagnostic Microbiology and Infectious Disease
dc.rights info:eu-repo/semantics/restrictedAccess
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subject antibody detection en_US
dc.subject Article en_US
dc.subject cohort analysis en_US
dc.subject controlled study en_US
dc.subject Diagnosis en_US
dc.subject diagnostic accuracy en_US
dc.subject diagnostic test accuracy study en_US
dc.subject Dual test en_US
dc.subject enzyme immunoassay en_US
dc.subject female en_US
dc.subject HIV en_US
dc.subject human en_US
dc.subject Human immunodeficiency virus infection en_US
dc.subject immunoreactivity en_US
dc.subject major clinical study en_US
dc.subject Peru en_US
dc.subject priority journal en_US
dc.subject Rapid test en_US
dc.subject sensitivity and specificity en_US
dc.subject syphilis en_US
dc.subject Treponema pallidum en_US
dc.subject Treponema pallidum hemagglutination test en_US
dc.title Dual rapid test for HIV and syphilis: A laboratory evaluation of the diagnostic accuracy of the Standard Q HIV/Syphilis Combo Test en_US
dc.type info:eu-repo/semantics/article
dc.identifier.doi https://doi.org/10.1016/j.diagmicrobio.2018.11.018
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#3.03.08
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#1.06.01
dc.relation.issn 1879-0070


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/restrictedAccess Except where otherwise noted, this item's license is described as info:eu-repo/semantics/restrictedAccess

Search DSpace


Browse

My Account

Statistics