dc.contributor.author |
Osorio, Lyda |
|
dc.contributor.author |
Carter, Nick |
|
dc.contributor.author |
Arthur, Preetam |
|
dc.contributor.author |
Bancone, Germana |
|
dc.contributor.author |
Gopalan, Sowmya |
|
dc.contributor.author |
Gupta, Sandeep K. |
|
dc.contributor.author |
Noedl, Harald |
|
dc.contributor.author |
Kochar, Sanjay K. |
|
dc.contributor.author |
Kochar, Dhanpat K. |
|
dc.contributor.author |
Krudsood, Srivicha |
|
dc.contributor.author |
Lacerda, Marcus V. |
|
dc.contributor.author |
Llanos Cuentas, Elmer Alejandro |
|
dc.contributor.author |
Rueangweerayut, Ronnatrai |
|
dc.contributor.author |
Srinivasan, Ramadurai |
|
dc.contributor.author |
Treiber, Moritz |
|
dc.contributor.author |
Mohrle, Jorg J. |
|
dc.contributor.author |
Green, Justin |
|
dc.date.accessioned |
2020-06-10T18:11:37Z |
|
dc.date.available |
2020-06-10T18:11:37Z |
|
dc.date.issued |
2015 |
|
dc.identifier.uri |
https://hdl.handle.net/20.500.12866/8042 |
|
dc.description.abstract |
Accurate diagnosis of glucose-6-phosphate dehydrogenase (G6PD) deficiency is required to avoid the risk of acute hemolysis associated with 8-aminoquinoline treatment. The performance of the BinaxNOW G6PD test compared with the quantitative spectrophotometric analysis of G6PD activity was assessed in 356 Plasmodium vivax-infected subjects in Brazil, Peru, Thailand, and India. In the quantitative assay, the median G6PD activity was 8.81 U/g hemoglobin (range = 0.05-20.19), with 11 (3%) subjects identified as deficient. Sensitivity of the BinaxNOW G6PD to detect deficient subjects was 54.5% (6 of 11), and specificity was 100% (345 of 345). Room temperatures inadvertently falling outside the range required to perform the rapid test (18-25 degrees C) together with subtlety of color change and insufficient training could partially explain the low sensitivity found. Ensuring safe use of 8-aminoquinolines depends on additional development of simple, highly sensitive G6PD deficiency diagnostic tests suitable for routine use in malaria-endemic areas. |
en_US |
dc.language.iso |
eng |
|
dc.publisher |
American Society of Tropical Medicine and Hygiene |
|
dc.relation.ispartofseries |
American Journal of Tropical Medicine and Hygiene (ASTMH Journal) |
|
dc.rights |
info:eu-repo/semantics/restrictedAccess |
|
dc.subject |
Point-of-Care Systems |
en_US |
dc.subject |
Antimalarials/therapeutic use |
en_US |
dc.subject |
Glycogen Storage Disease Type I/diagnosis |
en_US |
dc.subject |
Humans |
en_US |
dc.subject |
Malaria, Vivax/drug therapy |
en_US |
dc.subject |
Sensitivity and Specificity |
en_US |
dc.title |
Performance of BinaxNOW G6PD deficiency point-of-care diagnostic in P vivax-infected subjects |
en_US |
dc.type |
info:eu-repo/semantics/article |
|
dc.identifier.doi |
https://doi.org/10.4269/ajtmh.14-0298 |
|
dc.subject.ocde |
https://purl.org/pe-repo/ocde/ford#3.03.06 |
|
dc.relation.issn |
1476-1645 |
|