Correlación de la dosis de radiación calculada por el índice de dosis tomográfico y de la obtenida mediante la dosimetría luminiscente ópticamente estimulada en tomografías de cráneo usando un simulador

Mostrar el registro sencillo del ítem

dc.contributor.advisor Meca Castro, Edward Artemio es_ES
dc.contributor.advisor Loyola Sosa, Steev Orlando es_ES
dc.contributor.author Alvaro Rosales, Fiorella Victoria es_ES
dc.contributor.author Pereyra Cerna, Keyla Lorena es_ES
dc.date.accessioned 2021-06-24T21:57:58Z
dc.date.available 2021-06-24T21:57:58Z
dc.date.issued 2021
dc.identifier.other 103435 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/9562
dc.description.abstract Antecedentes: En tomografía computarizada, el método frecuente para el cálculo de dosis absorbida es el Índice de Dosis de Tomografía Computarizada (CTDI), sin embargo, diversos autores han reportado limitaciones en dicho método. Al contrario, los dosímetros luminiscentes ópticamente estimulados (OSLD) han demostrado ser un buen método debido a su alta sensibilidad y alto rango dinámico en la obtención de dosis puntuales. Objetivo: Se estimó la correlación entre la dosis de radiación calculada por el CTDI y la obtenida mediante la dosimetría OSL en tomografía de cráneo usando un simulador, de acuerdo a cada técnica tomográfica. Material y métodos: Se diseñaron y construyeron geometrías para la calibración y caracterización de los OSLD. Las irradiaciones fueron realizadas en un tomógrafo Toshiba Aquilion Prime 80. Además, se utilizó un simulador de polimetilmetacrilato de cráneo, cámara de ionización con electrómetro y OSLD con un lector microStar. La correlación por cada técnica tomográfica, fue estimada mediante la prueba estadística de R de Pearson. Resultados: Se observó en la primera técnica una correlación positiva (R=0,97) al utilizar el campo de visión (FoV) S, M y L entre la dosis calculada por el CTDI y la obtenida por los OSLD. Conclusión: Los resultados demuestran que existe una fuerte correlación positiva en la técnica 1. es_ES
dc.description.abstract Background: In computed tomography, the frequent method for calculating absorbed dose is the Computed Tomography Dose Index (CTDI), however, several authors have reported limitations for this method. On the other hand, optically stimulated luminescent dosimeters (OSLD) seems to be a good method due to their high sensitivity and high dynamic range for obtaining doses. Objective: The correlation was estimated between the radiation dose calculated by CTDI and that obtained by OSL dosimetry in the skull tomography process using a simulator, according to each tomographic technique. Material and methods: Geometries were designed and built for the calibration and characterization of the OSLDs. Irradiations were carried out on a Toshiba Aquilion Prime 80 tomograph. Also, a skull polymethylmethacrylate simulator, an ionization chamber with electrometer and OSLD with a microStar reader were used. The correlation for each tomographic technique was estimated using the Pearson R test. Results: A positive correlation (R = 0.97) was observed in the first technique when using the S, M and L field of view (FoV) between the dose calculated by the CTDI and that obtained by the OSLD. Conclusions: Results show that there is a strong positive correlation in technique 1. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Dosis de Radiación es_ES
dc.subject Dosimetría Luminiscente Ópticamente Estimulada es_ES
dc.subject Tomografía Computarizada es_ES
dc.subject Simulador es_ES
dc.title Correlación de la dosis de radiación calculada por el índice de dosis tomográfico y de la obtenida mediante la dosimetría luminiscente ópticamente estimulada en tomografías de cráneo usando un simulador es_ES
dc.title.alternative Correlation of calculated radiation dose by computed tomography dose index between estimated through optically stimulated luminescence dosimetry in skull tomographies using a simulator es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Licenciado en Tecnología Médica en la Especialidad de Radiología es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado es_ES
thesis.degree.discipline Tecnología Médica en la Especialidad de Radiología es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.12 es_ES
renati.author.dni 73271107
renati.author.dni 76381995
renati.advisor.orcid https://orcid.org/0000-0002-1226-9299 es_ES
renati.advisor.orcid https://orcid.org/0000-0001-5455-2423 es_ES
renati.advisor.dni 40569815
renati.advisor.dni 46384242
renati.type http://purl.org/pe-repo/renati/type#tesis es_ES
renati.level http://purl.org/pe-repo/renati/nivel#tituloProfesional es_ES
renati.discipline 915076 es_ES
renati.juror Márquez Pachas, José Fernando es_ES
renati.juror Rivero Mendoza, Marco Antonio es_ES
renati.juror Neyra Aguilar, Félix Alexander es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas