Universidad Peruana Cayetano Heredia

Effect of Abutment Geometry and Luting Agents on the Vertical Marginal Discrepancy of Cast Copings on Implant Abutments: An in Vitro Study

Mostrar el registro sencillo del ítem

dc.contributor.author Rosas, J.
dc.contributor.author Mayta-Tovalino, F.
dc.contributor.author Malpartida-Carrillo, V.
dc.contributor.author Degregori, A.M.
dc.contributor.author Mendoza, R.
dc.contributor.author Guerrero, M.E.
dc.date.accessioned 2021-10-04T23:00:57Z
dc.date.available 2021-10-04T23:00:57Z
dc.date.issued 2021
dc.identifier.uri https://hdl.handle.net/20.500.12866/9820
dc.description.abstract Aim. Vertical marginal discrepancy (VMD) influences the success of implant-supported restorations. However, there is little literature that has investigated the influence of geometry and cementing agent on changes in VMD of metal copings on implant abutments. The objective was to evaluate the effect of the geometry of the abutment and cementing agents on VMD. Methods. Cast copings were cemented on implant abutments customized cylindrical (4, 5.5, and 7 mm) and on hexagonal implant abutments (4 mm) cemented or uncemented molded copings were placed (n = 4, totally 64 samples) with different luting agents. The VMD of the copings were measured in the coping-abutment interface at three reference points using a stereomicroscope. The independent Student's t test was used for comparison between the two different abutment walls. The post hoc statistical analysis was performed by the Tukey test. Results. There was a significant VMD increase between noncemented and cemented cast copings using different luting agents. Abutment geometry and luting agents significantly influenced the VMD p≤0.05. Cylindrical abutment at 7 mm in height cemented with different luting agent tested showed significantly higher VMD values than cylindrical abutments of 4 mm p=0.019. Hexagonal abutments with a 4 mm height showed significantly higher VMD values than cylindrical 4 mm abutments using zinc oxide noneugenol and glass ionomer cements p=0.032. Conclusions. Abutment geometry and luting agents influence the VMD of cast copings cemented on implant abutment. The higher the cylindrical abutment, the greater the VMD, and hexagonal wall abutments promote greater marginal gap en_US
dc.language.iso eng
dc.publisher Hindawi
dc.relation.ispartofseries International Journal of Dentistry
dc.rights info:eu-repo/semantics/restrictedAccess
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subject Abutment Geometry en_US
dc.subject Luting Agents en_US
dc.subject Vertical Marginal Discrepancy en_US
dc.subject Cast Copings en_US
dc.subject Implant Abutments en_US
dc.title Effect of Abutment Geometry and Luting Agents on the Vertical Marginal Discrepancy of Cast Copings on Implant Abutments: An in Vitro Study en_US
dc.type info:eu-repo/semantics/article
dc.identifier.doi https://doi.org/10.1155/2021/9950972
dc.relation.issn 1687-8736


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/restrictedAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/restrictedAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas