Publicación:
Comparación de la precisión de mediciones antropométricas entre el método manual, escaneo facial con aplicativo móvil y escáner facial

dc.contributor.advisorLiñan Duran, Carlos Yuries_ES
dc.contributor.advisorChavez Alayo, Pablo Armandoes_ES
dc.contributor.authorRosales Rojas, Andreaes_ES
dc.date.accessioned2025-12-04T15:53:00Z
dc.date.available2025-12-04T15:53:00Z
dc.date.issued2025
dc.description.abstractObjetivo: Comparar la precisión de mediciones antropométricas faciales entre el método manual, escaneo facial con un aplicativo móvil y con un escáner facial. Metodología: Se realizó un estudio observacional, analítico y transversal. Los participantes fueron 20 estudiantes y docentes del Centro Dental Docente de la Universidad Peruana Cayetano Heredia. Un operador capacitado y calibrado midió 5 distancias de 9 puntos antropométricos faciales, utilizando 3 métodos: medición manual con un vernier digital (IP54-Black, Qfun), medición en 3D utilizando un escáner facial (RayFace, Ray) y una aplicación (Qlone, EyeCue Vision Technologies LTD) en un teléfono inteligente (Iphone 14Pro, Apple). Se estandarizaron las condiciones del ambiente y protocolo de cada método. Los escaneos del teléfono inteligente se exportaron al programa Meshlab para realizar las mediciones. Se aplicó las pruebas de Shapiro Wilk, prueba de ANOVA y prueba post hoc de Tukey, para el análisis estadísticos de los datos. Resultados: No hubo diferencias estadísticamente significativas en la precisión de las mediciones antropométricas entre los 3 métodos (p>0.05); pero sí en el tiempo de medición (p<0.001) entre el escaneo con aplicativo móvil comparado a los otros dos métodos. Conclusiones: La precisión de las medidas antropométricas obtenidas con el aplicativo móvil y el escáner facial son similares al método manual; sin embargo, se obtuvieron discrepancias mayores a 2 mm en las distancias CED-CEI y CD-CI con el método del aplicativo móvil. El escaneo facial con aplicativo móvil es el método más rápido.es_ES
dc.description.abstractObjective: To compare the accuracy of facial anthropometric measurements between the manual method and facial scanning with a mobile application and with a facial scanner. Methodology: An observational, analytical and cross-sectional study was carried out. The participants were 20 students and professors of the CDD at UPCH. A trained and calibrated operator marked 9 anthropometric reference points on participants and measured 5 distances, using 3 methods: manual measurement with a digital vernier (IP54-Black, Qfun), 3D measurement using a facial scanner (RayFace, Ray) and an application (Qlone, EyeCue Vision Technologies LTD) on a smartphone (Iphone 14Pro, Apple). The environmental conditions and protocol of each method were standardized. The images from the smartphone were exported to the Meshlab program to carry out the measurements. The Shapiro Wilk, Anova and post hoc Tukey test were applied for the statistical analysis. Results: There was no statistical difference on the precision of the anthropometric measurements between the three p>0.05); but there was a difference of the measurement time (p<0.001) between the mobile application scanner compared with the other two groups. Conclusions: The precision of the anthropometric measurements obtained with the three methods evaluated were similar. However, discrepancies greater than 2 mm were obtained in the CED-CEI and CD-CI distances when using the mobile application method. Also, the facial scanning with the mobile application was the fastest.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.other214598es_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12866/17970
dc.language.isospaes_ES
dc.publisherUniversidad Peruana Cayetano Herediaes_ES
dc.publisher.countryPEes_ES
dc.rightshttps://purl.org/coar/access_right/c_abf2es_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.eses_ES
dc.subjectAntropometríaes_ES
dc.subjectPrecisión de los Datoses_ES
dc.subjectImagen Tridimensionales_ES
dc.subjectTeléfono Inteligentees_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.12es_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14es_ES
dc.titleComparación de la precisión de mediciones antropométricas entre el método manual, escaneo facial con aplicativo móvil y escáner faciales_ES
dc.typehttp://purl.org/coar/resource_type/c_bdcces_ES
dspace.entity.typePublication
renati.advisor.dni10490448
renati.advisor.dni41664570
renati.advisor.orcidhttps://orcid.org/0000-0003-2669-842Xes_ES
renati.advisor.orcidhttps://orcid.org/0009-0003-2158-1684es_ES
renati.author.dni72630264
renati.discipline911057es_ES
renati.jurorDelgado Cotrina, Leyla Antoinettees_ES
renati.jurorOlivera Chacon, Hanzes_ES
renati.jurorAwuapara Flores, Shereenes_ES
renati.levelhttps://purl.org/pe-repo/renati/level#maestroes_ES
renati.typehttps://purl.org/pe-repo/renati/type#tesises_ES
thesis.degree.disciplineEstomatologíaes_ES
thesis.degree.grantorUniversidad Peruana Cayetano Heredia. Escuela de Posgrado Víctor Alzamora Castroes_ES
thesis.degree.nameMaestra en Estomatologíaes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Comparacion_RosalesRojas_Andrea.pdf
Tamaño:
1.08 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción: