Publicación:
Optimización de la verificación operacional en cromatógrafos de gases 456-GC Scion, analizadores de gas natural: análisis comparativo usando estándares de detectores (método convencional) y tres métodos de análisis (nueva metodología)

dc.contributor.advisorGarambel Vilca, Edson Emilioes_ES
dc.contributor.authorGuerreros Iñigo, Yony Jhonatanes_ES
dc.date.accessioned2024-06-13T14:27:05Z
dc.date.available2024-06-13T14:27:05Z
dc.date.issued2024
dc.description.abstractDurante la verificación operacional del cromatógrafo de gases, los clientes suelen cuestionar si una simple verificación de estándares para los detectores puede garantizar un rendimiento adecuado del cromatógrafo durante sus análisis. No obstante, la verificación operacional de un cromatógrafo de gases involucra una serie de criterios en cromatografía y criterios para la evaluación adecuada de un sistema cromatográfico. Esto incluye el manejo correcto del cromatógrafo de gases, así como manejo del software de control. Por ello, se busca optimizar este proceso de verificación operacional en el cromatógrafo de gases Analizadores. En la empresa Analytical, especializada en servicios de soporte analítico y técnico para equipos de laboratorio, me desempeño como responsable del área de cromatógrafos de gases. Durante la verificación operacional, nuestro principal objetivo es garantizar que el equipo responda de manera óptima en los análisis subsiguientes. No obstante, la efectividad de la verificación tradicional depende en gran medida de los detectores utilizados, lo que determina el tipo de estándar a emplear. Como parte de las mejoras propuestas en Analytical, se plantea una modificación en el procedimiento de verificación operacional del cromatógrafo de gases, en particular para los analizadores. Esta modificación implica utilizar el estándar específico del cliente durante la verificación, lo que aseguraría con mayor precisión que el equipo responde de manera adecuada a las demandas de análisis del cliente. Este cambio en el proceso de verificación se ha evaluado en función de su factibilidad, conveniencia y viabilidad para el cliente, además que se cuenta con lo necesario para realizarla y replicarla. Desde la perspectiva del cliente, esta propuesta supondría un ahorro económico, ya que no sería necesario adquirir un estándar adicional, sino que se utilizaría el mismo estándar empleado en sus análisis regulares.es_ES
dc.description.abstractDuring the operational verification of a gas chromatograph, customers often question whether a simple standards verification for the detectors can ensure proper chromatograph performance during their analyses. However, the operational verification of a gas chromatograph involves a series of criteria in chromatography and criteria for the proper evaluation of a chromatographic system. This includes the correct handling of the gas chromatograph as well as the control software. Therefore, the goal is to optimize this operational verification process in gas chromatograph analyzers. At Analytical, a company specializing in analytical and technical support services for laboratory equipment, I work as the head of the gas chromatograph department. During operational verification, our main goal is to ensure the equipment responds optimally in subsequent analyses. However, the effectiveness of traditional verification depends largely on the detectors used, which determines the type of standard to employ. As part of proposed improvements at Analytical, we suggest a modification in the operational verification procedure of the gas chromatograph, specifically for analyzers. This modification involves using the client's specific standard during verification, which would more accurately ensure the equipment responds appropriately to the client's analytical demands. This change in the verification process has been evaluated in terms of its feasibility, convenience, and viability for the client, and we have everything necessary to perform and replicate it. From the client's perspective, this proposal would result in cost savings as they would not need to purchase an additional standard; instead, they would use the same standard employed in their regular analyses.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.other214319es_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12866/15503
dc.language.isospaes_ES
dc.publisherUniversidad Peruana Cayetano Herediaes_ES
dc.publisher.countryPEes_ES
dc.rightshttps://purl.org/coar/access_right/c_abf2es_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.eses_ES
dc.subjectCromatógrafo de Gaseses_ES
dc.subjectVerificación Operacionales_ES
dc.subjectAnálisis de Hidrocarburoses_ES
dc.subjectIndustria Gas Naturales_ES
dc.subjectCromatógrafo de Gases 456-GC Sciones_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.04.02es_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.04.07es_ES
dc.titleOptimización de la verificación operacional en cromatógrafos de gases 456-GC Scion, analizadores de gas natural: análisis comparativo usando estándares de detectores (método convencional) y tres métodos de análisis (nueva metodología)es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1fes_ES
dspace.entity.typePublication
renati.advisor.dni44149549
renati.advisor.orcidhttps://orcid.org/0000-0002-7404-3914es_ES
renati.author.dni72747003
renati.discipline531066es_ES
renati.jurorGuzmán Lezama, Enrique Godofredoes_ES
renati.jurorAviles Pavon, Martha Kellyes_ES
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_ES
renati.typehttps://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales_ES
thesis.degree.disciplineQuímicaes_ES
thesis.degree.grantorUniversidad Peruana Cayetano Heredia. Facultad de Ciencias e Ingeniería Alberto Cazorla Talleries_ES
thesis.degree.nameLicenciado en Químicaes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Optimizacion_GuerrerosIñigo_Yony.pdf
Tamaño:
1.68 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones