Publicación:
Validación del software LabX integrado a un espectrofotómetro UV-Vis para asegurar la integridad de datos en un laboratorio farmacéutico en Lima, Perú

dc.contributor.advisorOrihuela Echavigurin, Roberto Michaeles_ES
dc.contributor.authorPortier Noriega, Sophie Guadalupees_ES
dc.date.accessioned2025-10-10T15:22:37Z
dc.date.available2025-10-10T15:22:37Z
dc.date.issued2025
dc.description.abstractGarantizar la integridad de los datos generados durante la producción farmacéutica es crucial en un sector altamente regulado, puesse tiene que preservar la seguridad y eficacia de los productos farmacéuticos. Para lograr la integridad de datos, estos tienen que ser atribuibles, legibles, contemporáneos, originales, precisos, completos, coherentes, perdurables y disponibles, cumpliendo de esa manera con los principios ALCOA+. Debido al avance tecnológico se producen grandes cantidades de datos, especialmente en un laboratorio farmacéutico donde se emplean equipos analíticos asociados a un software. Asimismo, la normativa exige a las empresas farmacéuticas el desarrollo y aplicación de procedimientos exhaustivos que protejan la calidad de los datos a lo largo de su ciclo de vida. Por lo tanto, es imprescindible llevar a cabo un proceso de validación para asegurar la integridad de los datos generados por un software. El presente trabajo aborda el proceso de validación del software LabX del espectrofotómetro UV-VIS Mettler Toledo modelo UV7. De manera preliminar se definieron las especificaciones de requisitos de usuario (URS) y se realizó el análisis de riesgo del software LabX. La validación del software mencionado constó de tres etapas principales: calificación de instalación (IQ), calificación de operación (OQ) y calificación de desempeño (PQ). En cada etapa se ejecutaron diferentes pruebas para verificar que el software estuviera instalado y configurado correctamente, funcionara según lo descrito por el fabricante, fuera adecuado para su uso previsto y garantizara la integridad de los datos que administre. Cabe precisar que, en la práctica, la validación del software LabX y la calificación del espectrofotómetro UV-VIS se realizaron de forma simultánea; sin embargo, este trabajo se centra exclusivamente en el software. Los resultados obtenidos 2 demostraron su correcta instalación, funcionamiento y conexión con el equipo, así como su cumplimiento con lo establecido por el CFR 21 Parte 11.es_ES
dc.description.abstractEnsuring the integrity of the data generated during pharmaceutical production is crucial in a highly regulated industry because the safety and efficacy of pharmaceutical products must be preserved. To achieve data integrity, data must be attributable, legible, contemporaneous, original, accurate, complete, consistent, enduring and available, in line with the ALCOA+ principles. Technological advances generate large amounts of data, especially in a pharmaceutical laboratory where analytical equipment linked to software is used. In addition, regulations require pharmaceutical companies to develop and implement comprehensive procedures to protect data quality throughout its life cycle. Considering the above, it is essential to carry out a validation process to ensure the integrity of the data generated by software. This report focused on the validation process of the LabX software of the Mettler Toledo UV-VIS spectrophotometer model UV7. Preliminary user requirements specification (URS) was defined and a risk analysis of the LabX software was performed. Validation of the mentioned software consisted of three main stages: installation qualification (IQ), operation qualification (OQ) and performance qualification (PQ). Different tests were carried out in each stage to evaluate and document that the LabX software was correctly installed and configured, worked as described by the manufacturer, was suitable for its intended use and guaranteed data integrity. In practice, the LabX software was validated and the UV-VIS spectrophotometer was qualified simultaneously. However, this report exclusively focuses on the software. The results demonstrated its correct installation, operation, and connection to the equipment, as well as compliance with 21 CFR Part 11.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.other219518es_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12866/17748
dc.language.isospaes_ES
dc.publisherUniversidad Peruana Cayetano Herediaes_ES
dc.publisher.countryPEes_ES
dc.rightshttps://purl.org/coar/access_right/c_abf2es_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.eses_ES
dc.subjectIntegridad de datoses_ES
dc.subjectValidación de softwarees_ES
dc.subjectCFR 21 Parte 11es_ES
dc.subjectEspectrofotómetro UV-VISes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.04.00es_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.01.05es_ES
dc.titleValidación del software LabX integrado a un espectrofotómetro UV-Vis para asegurar la integridad de datos en un laboratorio farmacéutico en Lima, Perúes_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1fes_ES
dspace.entity.typePublication
renati.advisor.dni40432215
renati.advisor.orcidhttps://orcid.org/0000-0003-4232-0419es_ES
renati.author.dni70439773
renati.discipline917046es_ES
renati.jurorAlva Bazalar, Norma Fabiolaes_ES
renati.jurorValverde Tapia, David Elies_ES
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_ES
renati.typehttps://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales_ES
thesis.degree.disciplineFarmacia y Bioquímicaes_ES
thesis.degree.grantorUniversidad Peruana Cayetano Heredia. Facultad de Ciencias e Ingenieríaes_ES
thesis.degree.nameQuímico Farmacéuticoes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Validación_PortierNoriega_Sophie.pdf
Tamaño:
2.15 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción: