Universidad Peruana Cayetano Heredia

Concordancia de los sistemas digitales Nemoscan, Omnicam e InEosX 3D para la medición de 6 piezas y 4 distancias dentarias en niveles de apiñamiento

Mostrar el registro sencillo del ítem

dc.contributor.advisor Salazar Silva, Raúl Fernando es_ES
dc.contributor.author Bravo Calderón, Manuel Estuardo es_ES
dc.date.accessioned 2022-06-24T21:55:38Z
dc.date.available 2022-06-24T21:55:38Z
dc.date.issued 2022
dc.identifier.other 203498 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/11829
dc.description.abstract Los escáneres digitales cada vez se encuentran más al alcance de los profesionales de ortodoncia por lo que es necesario evaluar su concordancia considerando las condiciones de apiñamiento de la arcada de los pacientes, estudios realizados hasta ahora no han evaluado a los escáneres intra (Omnicam) y extraorales (InEosX y Nemoscan) con respecto al gold standard. El presente estudio tiene el propósito de establecer la fiabilidad de los sistemas digitales NEMOSCAN, OMNICAM e INEOSX 3D para la medición de piezas y arcadas dentarias con y sin apiñamiento dental. A través de dos observadores que anteriormente no han utilizado escáneres 3D se realizó impresiones digitales en las arcadas de 36 pacientes, de cada uno se obtuvo 10 mediciones (agrupadas en cuatro grupos nueve pacientes según el nivel de apiñamiento). Luego de una capacitación, cada observador realizó su propia impresión. Se evaluó la concordancia de las mediciones entre cada sistema digital con el gold standard con el Coeficiente de Correlación Intraclase (CCI). Los resultados muestran que los promedios de todos los casos presentan una fiabilidad muy alta tanto para las medidas intraobservador como para las medidas interobservador (CCI˃0,800). Así como se comparó las medidas de estos dos observadores con la prueba ANOVA de un factor para determinar la precisión de dichas mediciones sin encontrar diferencias significativas (p˂0,001). Se ha establecido que la fiabilidad de los sistemas digitales NEMOSCAN, OMNICAM e INEOSX 3D para la medición de piezas y arcadas dentarias con y sin apiñamiento dental es la misma que la medición realizada con el gold standard mediante calibrador digital manual. La ausencia de apiñamiento, así como la presencia de apiñamiento leve, moderado o severo, no constituye un factor que afecte a la fiabilidad de las mediciones. es_ES
dc.description.abstract Digital scanners are increasingly available to orthodontic professionals, so it is necessary to evaluate their concordance considering the crowding conditions of the patients' arches, studies carried out so far have not evaluated intra (Omnicam ) and extraoral (InEosX and Nemoscan) with respect to the gold standard. The present study aims to establish the reliability of the NEMOSCAN, OMNICAM and INEOSX 3D digital systems for the measurement of teeth and dental arches with and without dental crowding. Digital impressions were made in the arches of 36 patients by two observers who had not previously used 3D scanners; 10 measurements were obtained from each one (nine patients grouped into four groups according to the level of crowding). After a training, each observer made his own impression. The concordance of the measurements between each digital system was evaluated with the gold standard with the Intraclass Correlation Coefficient (ICC). The results show that the averages of all the cases present a very high reliability for both the intraobserver measures and the interobserver measures (ICC˃0,800). In addition, the measurements of these two observers were compared with the one-way ANOVA test to determine the precision of the measurements without finding significant differences (p˂0,001). It has been established that the reliability of the NEMOSCAN, OMNICAM and INEOSX 3D digital systems for the measurement of teeth and dental arches with and without dental crowding is the same as the measurement performed with the gold standard using a manual digital caliper. The absence of crowding, as well as the presence of mild, moderate or severe crowding, does not constitute a factor that affects the reliability of the measurements. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Apiñamiento es_ES
dc.subject Confiabilidad es_ES
dc.subject Escáner Dental 3D es_ES
dc.subject Precisión es_ES
dc.title Concordancia de los sistemas digitales Nemoscan, Omnicam e InEosX 3D para la medición de 6 piezas y 4 distancias dentarias en niveles de apiñamiento es_ES
dc.type info:eu-repo/semantics/doctoralThesis es_ES
thesis.degree.name Doctor en Estomatología es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira es_ES
thesis.degree.discipline Estomatología es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.12 es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.14 es_ES
renati.author.dni 102137460
renati.advisor.orcid https://orcid.org/0000-0002-9815-3309 es_ES
renati.advisor.dni 07566516
renati.type http://purl.org/pe-repo/renati/type#tesis es_ES
renati.level http://purl.org/pe-repo/renati/nivel#doctor es_ES
renati.discipline 911018 es_ES
renati.juror Cabezas Bernhardt, Gerson Oswaldo es_ES
renati.juror Castillo Cevallos, Jorge Luis es_ES
renati.juror Carbajal Arroyo, Luz Aurora es_ES
renati.juror Castillo Andamayo, Diana Esmeralda es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas