Universidad Peruana Cayetano Heredia

Influencia de lámparas de polimerización sobre la microdureza de dos resinas bulk fill

Mostrar el registro sencillo del ítem

dc.contributor.advisor Delgado Cotrina, Leyla Antoinette es_ES
dc.contributor.advisor Tay Chu Jon, Lidia Yileng es_ES
dc.contributor.author Salazar Ramos, Patsi es_ES
dc.date.accessioned 2024-02-19T19:32:00Z
dc.date.available 2024-02-19T19:32:00Z
dc.date.issued 2023
dc.identifier.other 209738 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/15014
dc.description.abstract Antecedentes: Existen dispositivos de luz de alta intensidad con diferentes características y esto puede influenciar en las propiedades de las resinas compuestas bulk fill, que son utilizadas en grandes incrementos y necesitan cierta irradiancia para polimerizar correctamente. Objetivo: Evaluar la influencia de diferentes lámparas de polimerización sobre la microdureza de dos resinas bulk fill. Materiales y métodos: Se confeccionaron discos de 5x5x4 mm utilizando un solo incremento de 4mm de las resinas bulk fill color A2. Luego, se fotopolimerizaron con las siguientes lámparas LED: Valo (Ultradent, South Jordan, EE.UU.), Elipar L (3M ESPE, St. Paul, EE.UU), LED F (Woodpecker Medical Instrument Co., Guilin, China) y Noblesse (Max Dental Co, Bucheon-si, Gyeonggi, Corea). La microdureza superficial de Vickers MMT (Buelher) se evaluó en la superficie superior e inferior de cada disco, y con ello se determinó la profundidad de polimerización. Después de 24 horas, se obtuvieron y analizaron los datos mediante un ANOVA y la prueba Scheffé con un nivel de confianza de 0.5%. Resultados: Para la resina Filtek One Bulk Fill®, no se encontró diferencias estadísticamente significativas (p>0.05) con las diferentes lámparas. Sin embargo, para la resina Opus Bulk Fill APS® se encontró los menores valores utilizando la lámpara Elipar L y Noblesse. Conclusión: Las lámparas de fotopolimerización no influyen sobre la microdureza en la resina Filtek One Bulk Fill®, pero en la resina Opus Bulk Fill APS® las lámparas Valo y LED F tuvieron los mayores valores de microdureza. es_ES
dc.description.abstract Background: There are high intensity light devices with different characteristics and this can influence the properties of bulk fill composite resins, which are used in large increments and require certain irradiance to polymerize correctly. Objective: To evaluate the influence of different curing lights on the microhardness of two bulk fill resins. Materials and methods: Discs of 5x5x4 mm were made using a single 4mm increment of A2 color bulk fill resins. Then, they were lightcured with the following LED lamps: Valo (Ultradent, South Jordan, USA), Elipar L (3M ESPE, St. Paul, USA), LED F (Woodpecker Medical Instrument Co., Guilin, China ) and Noblesse (Max Dental Co, Bucheon-si, Gyeonggi, Korea). The surface microhardness of Vickers MMT (Buelher) was evaluated on the upper and lower surface of each disc, and with this the polymerization depth was determined. After 24 hours, data were obtained and analyzed using ANOVA and the Scheffé test with a confidence level of 0.5%. Results: For Filtek One Bulk Fill® resin, no statistically significant differences (p>0.05) were found with the different lamps. However, for the Opus Bulk Fill APS® resin, the lowest values were found using the Elipar L and Noblesse lamp. Conclusion: The light-curing lamps do not influence the microhardness in the Filtek One Bulk Fill® resin, but in the Opus Bulk Fill APS® resin the Valo and LED F lamps had the highest microhardness values. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Polimerización es_ES
dc.subject Resinas Compuestas es_ES
dc.subject Dureza es_ES
dc.title Influencia de lámparas de polimerización sobre la microdureza de dos resinas bulk fill es_ES
dc.title.alternative Influence of curing lights on the microhardness of two bulk fill resins es_ES
dc.type info:eu-repo/semantics/monograph es_ES
thesis.degree.name Segunda Especialidad Profesional en Odontología Restauradora y Estética es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira es_ES
thesis.degree.discipline Odontología Restauradora y Estética es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.14 es_ES
renati.author.dni 46880212
renati.advisor.orcid https://orcid.org/0000-0002-3027-178X es_ES
renati.advisor.orcid https://orcid.org/0000-0002-1656-2804 es_ES
renati.advisor.dni 10193841
renati.advisor.dni 41875787
renati.type http://purl.org/pe-repo/renati/type#tesis es_ES
renati.level http://purl.org/pe-repo/renati/nivel#tituloSegundaEspecialidad es_ES
renati.discipline 911209 es_ES
renati.juror Mas Lopez, Janett es_ES
renati.juror Henostroza Quintans, Natalia es_ES
renati.juror Cuadros Sanchez, Johanna Lizbeth es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas