Mostrar el registro sencillo del ítem
dc.contributor.advisor | Tay Chu Jon, Lidia Yileng | es_ES |
dc.contributor.advisor | Delgado Cotrina, Leyla Antoinette | es_ES |
dc.contributor.author | Trujillo Flores, Stephany | es_ES |
dc.date.accessioned | 2025-01-31T21:30:52Z | |
dc.date.available | 2025-01-31T21:30:52Z | |
dc.date.issued | 2024 | |
dc.identifier.other | 213943 | es_ES |
dc.identifier.uri | https://hdl.handle.net/20.500.12866/16632 | |
dc.description.abstract | La Microdureza superficial de las resinas Bulk Fill pueden ser influenciadas de diversas maneras ya sea por el tipo de lámpara, composición de la resina o tiempo de fotopolimerización En base a ello, el objetivo de este estudio fue evaluar la Microdureza superficial de las resinas Bulk Fill luego de la fotopolimerización con diferentes lámparas LED en tiempos de 20 y 40 segundos. El diseño del estudio fue experimental in vitro, las muestras estuvieron conformadas por especímenes de resina de forma circular con diámetro de 5 mm x4 mm de altura (n=5), se evaluaron las resinas Filtek Bulk Fill (3M) color A2 y Tetric N Ceram Bulk Fill (Ivoclar) color A2 fotopolimerizadas con las lámparas Valo™ Grand (Ultradent), Elipar™ Deep Cure-L (3M), Woodpecker Led F (Woodpecker), Bluephase N MC (Ivoclar) durante 20 y 40 segundos. Se evaluó la microdureza de todas las muestras en la parte superior e inferior, con el microdurómetro de Vickers. Se utilizó la prueba Anova/Tukey para poder determinar las diferencias significativas entre los valores obtenidos según las resinas, las lámparas de fotopolimerización y el tiempo. El nivel de confianza fue de un 95% con un valor de p<0.05. La resina Bulk Fill (3M) color A2 tuvo mejores valores de Microdureza con la lámpara Woodpecker Led F (Woodpecker) presentando diferencia significativa respecto a las demás lámparas a los 20 segundos y la resina Tetric N Ceram Bulk Fill (Ivoclar) color A2 presentó mejores valores con la lámpara Valo™ Grand (Ultradent) con diferencia significativa a los 20 segundos. Los valores de Microdureza superficial fueron aceptables en ambas resinas pero se identificó que pueden variar de acuerdo al tipo de lámpara y a la composición (coiniciadores, monómeros) que presenta cada resina. | es_ES |
dc.description.abstract | The surface microhardness of Bulk Fill resins can be influenced in several ways either by the type of lamp, resin composition or light curing time. Based on this, the objective of this study was to evaluate the surface microhardness of Bulk Fill resins after light curing with different LED lamps at times of 20 and 40 seconds. The design of the study was experimental in vitro, the samples consisted of circular resin specimens with a diameter of 5 mm x 4 mm in height (n=5), Filtek Filtek One Bulk Fill (3M) color A2 and Tetric N Ceram Bulk Fill (Ivoclar) color A2 resins light cured with Valo™ Grand (Ultradent), Elipar™ Deep Cure-L (3M), Woodpecker Led F (Woodpecker), Bluephase N MC (Ivoclar) lamps for 20 and 40 seconds were evaluated. The microhardness of all specimens was evaluated at the top and bottom, using Vickers microhardness tester. The Anova/Tukey test was used to determine the significant differences between the values obtained according to resins, light-curing lamps and time. The confidence level was 95% with a value of p<0.05. The Bulk Fill resin (3M) color A2 had better Microhardness values with the Woodpecker Led F lamp (Woodpecker) presenting a significant difference with respect to the other lamps at 20 seconds and the Tetric N Ceram Bulk Fill resin (Ivoclar) color A2 presented better values with the Valo™ Grand lamp (Ultradent) with a significant difference at 20 seconds. The surface microhardness values were acceptable in both resins but it was identified that they can vary according to the type of lamp and the composition (co-initiators, monomers) that each resin presents. | es_ES |
dc.format | application/pdf | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad Peruana Cayetano Heredia | es_ES |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | es_ES |
dc.subject | Resinas | es_ES |
dc.subject | Polimerización | es_ES |
dc.subject | Lámparas | es_ES |
dc.title | Microdureza superficial de resinas Bulk Fill según tiempo de fotopolimerización de diferentes lámparas LED | es_ES |
dc.title.alternative | Surface microhardness of Bulk Fill resins according to the light curing time of different LED lamps | es_ES |
dc.type | info:eu-repo/semantics/monograph | es_ES |
thesis.degree.name | Segunda Especialidad Profesional en Odontología Restauradora y Estética | es_ES |
thesis.degree.grantor | Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira | es_ES |
thesis.degree.discipline | Odontología Restauradora y Estética | es_ES |
dc.publisher.country | PE | es_ES |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#3.02.14 | es_ES |
renati.author.dni | 47549131 | |
renati.advisor.orcid | https://orcid.org/0000-0002-1656-2804 | es_ES |
renati.advisor.orcid | https://orcid.org/0000-0002-3027-178X | es_ES |
renati.advisor.dni | 41875787 | |
renati.advisor.dni | 10193841 | |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_ES |
renati.level | https://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad | es_ES |
renati.discipline | 911209 | es_ES |
renati.juror | Mas Lopez, Janett | es_ES |
renati.juror | Henostroza Quintans, Natalia | es_ES |
renati.juror | Ordoñez Reyes, Leydi Fiorela | es_ES |