Universidad Peruana Cayetano Heredia

Análisis mediante elementos finitos del efecto biomecánico de los dientes anterosuperiores según longitudes del brazo de poder durante la retracción en masa

Mostrar el registro sencillo del ítem

dc.contributor.advisor Leon Manco, Roberto Antonio es_ES
dc.contributor.author Pachas Yarleque, Luis Enrique es_ES
dc.date.accessioned 2025-05-23T21:02:42Z
dc.date.available 2025-05-23T21:02:42Z
dc.date.issued 2025
dc.identifier.other 218149 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/17095
dc.description.abstract Introducción: La retracción de los dientes anterosuperiores tras la extracción de primeros premolares constituye una estrategia terapéutica frecuente en ortodoncia, particularmente en pacientes con biprotrusión o maloclusiones Clase II que requieren control absoluto del anclaje. El uso de mini-implantes ha optimizado la estabilidad de los dientes posteriores durante el cierre de espacios, permitiendo un mayor control biomecánico. Objetivo: Analizar el comportamiento biomecánico de los dientes anterosuperiores mediante simulaciones computacionales basadas en el método de elementos finitos, evaluando el efecto de distintas alturas del brazo de poder en combinación con dos prescripciones de brackets (Roth y MBT), dos ubicaciones de mini-implantes y dos tipos de material del arco ortodóntico (acero inoxidable y TMA). Materiales y métodos: Se llevará a cabo un estudio prospectivo, experimental y computacional, utilizando modelos tridimensionales que incluirán dientes, mini-implantes y arcos ortodónticos. Se considerarán como variables la altura del brazo de poder (variable independiente), el comportamiento biomecánico de los dientes anterosuperiores (variable dependiente) y, como covariables, la prescripción de brackets, la ubicación del mini-implante y el material del arco ortodóntico. Conclusiones: Se espera que los resultados proporcionen evidencia cuantitativa comparativa que contribuya a optimizar la planificación clínica de tratamientos ortodónticos que requieran retracción en masa asistida con anclaje esquelético, favoreciendo el control tridimensional del movimiento dentario. es_ES
dc.description.abstract Introduction: The retraction of maxillary anterior teeth following the extraction of first premolars is a common therapeutic strategy in orthodontics, particularly in patients with bimaxillary protrusion or Class II malocclusions requiring absolute anchorage control. The use of mini-implants has optimized the stability of posterior teeth during space closure, allowing for greater biomechanical control. Objective: To analyze the biomechanical behavior of maxillary anterior teeth through computational simulations using the finite element method, evaluating the effect of different power arm heights in combination with two bracket prescriptions (Roth and MBT), two mini-implant positions, and two types of archwire material (stainless steel and TMA). Materials and Methods: A prospective, experimental, and computational study will be conducted using three-dimensional models that include teeth, mini-implants, and orthodontic archwires. The power arm height will be considered as the independent variable, the biomechanical behavior of the maxillary anterior teeth as the dependent variable, and the bracket prescription, mini-implant position, and archwire material as covariables. Conclusions: The expected outcomes aim to provide comparative quantitative evidence that contributes to optimizing clinical planning in orthodontic treatments requiring en-masse retraction with skeletal anchorage, thereby enhancing tridimensional control of dental movement. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Ortodoncia es_ES
dc.subject Métodos de Anclaje en Ortodoncia es_ES
dc.subject Cierre del Espacio Ortodóncico es_ES
dc.subject Aparatos Ortodóncicos Fijos es_ES
dc.title Análisis mediante elementos finitos del efecto biomecánico de los dientes anterosuperiores según longitudes del brazo de poder durante la retracción en masa es_ES
dc.title.alternative Finite element analysis of the biomechanical effect on maxillary anterior teeth according to power arm lengths during en-masse retraction es_ES
dc.type info:eu-repo/semantics/monograph es_ES
thesis.degree.name Especialista en Ortodoncia y Ortopedia Maxilar es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira es_ES
thesis.degree.discipline Ortodoncia y Ortopedia Maxilar es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.14 es_ES
renati.author.dni 70383041
renati.advisor.orcid https://orcid.org/0000-0001-9641-1047 es_ES
renati.advisor.dni 43649284
renati.type https://purl.org/pe-repo/renati/type#trabajoAcademico es_ES
renati.level https://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad es_ES
renati.discipline 911269 es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas