DSpace Repository

“Detección de la liberación de endotoxinas bacterianas inducidas por la esterilización mediante autoclave bajo las condiciones recomendadas por el Ministerio de Salud- Perú”.

Show simple item record

dc.contributor.advisor Sheen Cortavarría, Patricia es_ES
dc.contributor.author Valenza Trujillo, Omar Denilson es_ES
dc.date.accessioned 2025-07-03T23:22:47Z
dc.date.available 2025-07-03T23:22:47Z
dc.date.issued 2025
dc.identifier.other 212248 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/17342
dc.description.abstract Las condiciones de esterilización recomendadas por el Ministerio de Salud- Perú en el “Manual de Desinfección y Esterilización -2021” son de 121°C por 15 minutos y 134°C por 3 minutos, la biocarga de los materiales hospitalarios a esterilizar incluyen bacterias Gramnegativas portadoras de endotoxinas bacterianas como Escherichia coli y Salmonella enterica, se desconoce si la muerte celular inducida por el vapor mediante la alteración de las estructuras celulares y la coagulación de las proteínas durante la esterilización por autoclave pueda generar la liberación de endotoxinas resistentes a la esterilización que puedan causar efectos que incluyen fiebre, escalofríos, neumonitis tóxica, síntomas respiratorios y en el peor de los casos shock sépticos sobre pacientes con estancia hospitalaria usuarios de estos materiales esterilizados, estos materiales incluyen equipos de curación, equipos de sutura, instrumentación quirúrgica, ropa para sala de operaciones, campos simples y fenestrados, apósitos, etc. Se detectó por el método de Gel-Clot la liberación de endotoxinas bacterianas de inóculos estandarizados de E.coli ATCC8739 y S. enterica ATCC 14028 dispuestos dentro de materiales hospitalarios tras esterilización por autoclave a 121°C por 15 minutos y 134°C por 3 minutos. Los resultados evidencian que en todos los inóculos E.coli y S. enterica sometidos a procesos de esterilización ya sea a 121°C y 134°C se detectó resultados positivos para la liberación de endotoxinas con porcentajes de positividad que varían entre el 11.1% hasta 88.9%, respectivamente; aumentando el porcentaje de positividad de la liberación de endotoxinas en función de la temperatura esterilización y sin impacto por el tipo de bacteria Gram-negativa sometida a esterilización. es_ES
dc.description.abstract The sterilization conditions recommended by the Ministry of Health - Peru in the "Disinfection and Sterilization Manual -2021" are 121 ° C for 15 minutes and 134 ° C for 3 minutes, the bioburden of the hospital materials to be sterilized include pathogenic Gramnegative bacteria carriers of bacterial endotoxins such as Escherichia coli and Salmonella enterica, it is unknown whether steam-induced cell death by altering cellular structures and protein coagulation during autoclave sterilization can generate the release of sterilization-resistant endotoxins that can cause effects including fever, chills, toxic pneumonitis, respiratory symptoms and in the worst case septic shock on patients with hospital stay users of these sterilized materials, these materials include healing equipment, suture equipment, surgical instrumentation, operating room clothing, simple and fenestrated fields, dressings, etc. The release of bacterial endotoxins from standardized inoculums of E. coli ATCC8739 and S. enterica ATCC 14028 placed inside hospital materials after autoclaving at 121°C for 15 minutes and 134°C for 3 minutes was evaluated by the Gel-Clot method. The results show that all E. coli and S. enterica inocula subjected to sterilization processes at either 121°C or 134°C showed positive results for endotoxin release, with positivity rates ranging from 11.1% to 88.9%, respectively; the positivity rate for endotoxin release increased depending on the sterilization temperature and was not affected by the type of Gram-negative bacteria subjected to sterilization. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Esterilización es_ES
dc.subject Endotoxinas es_ES
dc.subject Gel-Clot es_ES
dc.subject E.coli ATCC8739 es_ES
dc.subject S. enterica ATCC 14028 es_ES
dc.title “Detección de la liberación de endotoxinas bacterianas inducidas por la esterilización mediante autoclave bajo las condiciones recomendadas por el Ministerio de Salud- Perú”. es_ES
dc.type info:eu-repo/semantics/masterThesis es_ES
thesis.degree.name Maestro en Microbiología es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Escuela de Posgrado Víctor Alzamora Castro es_ES
thesis.degree.discipline Microbiología es_ES
dc.publisher.country PE es_ES
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#1.06.01 es_ES
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#3.01.03 es_ES
renati.author.dni 44373860
renati.advisor.orcid https://orcid.org/0000-0002-7118-9301 es_ES
renati.advisor.dni 09541127
renati.type https://purl.org/pe-repo/renati/type#tesis es_ES
renati.level https://purl.org/pe-repo/renati/level#maestro es_ES
renati.discipline 511247 es_ES
renati.juror Verastegui Pimentel, Manuela Renee es_ES
renati.juror Cristobal Delgado, Ruth Liliana es_ES
renati.juror Chile Andrade, Nancy es_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess

Search DSpace


Browse

My Account

Statistics