Universidad Peruana Cayetano Heredia

Descontaminación de la superficie del implante mediante el tratamiento quirúrgico de la periimplantitis: una revisión sistemática

Mostrar el registro sencillo del ítem

dc.contributor.advisor Alarcón Palacios, Marco Antonio es_ES
dc.contributor.advisor Ariza Fritas, Tania es_ES
dc.contributor.author Flores Chipana, Lourdes Vanesa es_ES
dc.contributor.author Pisconte León, Wendy Carolina es_ES
dc.date.accessioned 2022-08-11T22:57:41Z
dc.date.available 2022-08-11T22:57:41Z
dc.date.issued 2022
dc.identifier.other 205355 es_ES
dc.identifier.uri https://hdl.handle.net/20.500.12866/12007
dc.description.abstract Objetivo: Evaluar el método más efectivo de descontaminación de la superficie del implante en el tratamiento quirúrgico de la periimplantitis mediante una revisión sistemática. Materiales y métodos: Se realizaron búsquedas electrónicas de ensayos clínicos aleatorizados (ECAS) en tres bases de datos: la Biblioteca Nacional de Medicina (MEDLINE), el Registro Cochrane Central de Ensayos Controlados (CENTRAL) y Web of Science (WOS). Los resultados fueron limitados a estudios en humanos. Sólo se incluyeron artículos en inglés. El riesgo de sesgo de los ECAs se evaluó mediante la herramienta Cochrane. Resultados: Se identificaron un total de 96 artículos, de los cuales 10 artículos se incluyeron en la presente revisión. Los descontaminantes de la superficie del implante que se encontraron en los ECAs en esta revisión sistemática fueron: Clorhexidina al 0,2% y 2%, Clorhexidina al 0,12% en combinación con Cloruro de Cetilpiridino al 0,05%; antibiótico sistémico acompañado con Clorhexidina al 0.2%; el uso de Er: YAG laser; terapia de ozono; aire abrasivo. Siete de los ECAs cumplieron con todos los parámetros de la herramienta Cochrane obteniendo un bajo riesgo de sesgo y los tres restantes, un riesgo de sesgo medio. Conclusiones: Hasta la actualidad no existe ningún descontaminante para la superficie del implante que muestre una superioridad frente a otro. Asimismo, no se encontraron diferencias significativas entre los descontaminantes frente al desbridamiento mecánico solo. Se necesitan ensayos clínicos aleatorizados bien controlados, que comparen diferentes tipos de coadyuvantes entre sí y con un tiempo de seguimiento mayor o igual a los 12 meses. es_ES
dc.description.abstract Objective: To evaluate the most effective method of decontamination of the implant surface in the surgical treatment of peri-implantitis using a systematic review. Materials and methods: Three databases were electronically searched for randomized clinical trials (RCTs): the National Library of Medicine (MEDLINE), the Cochrane Central Register of Controlled Trials (CENTRAL), and the Web of Science (WOS). The results were limited to human studies. Only articles in English were included. The risk of bias of the RCTs was assessed using the Cochrane tool. Results: A total of 96 articles were identified, of which 10 articles were included in the present review. The implant surface decontaminants found in the RCTs in this systematic review were: 0.2% and 2% Chlorhexidine, 0.12% Chlorhexidine in combination with 0.05% Cetylpyridine Chloride; systemic antibiotic accompanied with 0.2% Chlorhexidine; the use of Er: YAG laser; ozone therapy; abrasive air. Seven of the RCTs assessed all the parameters of the Cochrane tool obtaining a low risk of bias and the remaining three, a medium risk of bias. Conclusions: Until now there is no decontaminant for the implant surface that shows superiority over others. In addition, no significant differences were found between any decontaminant of the implant surface versus mechanical debridement alone. Well-controlled randomized clinical trials are needed, comparing different types of adjuvants with each other and with a follow-up time greater than or equal to 12 months. es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Peruana Cayetano Heredia es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es es_ES
dc.subject Periimplantitis es_ES
dc.subject Descontaminación es_ES
dc.subject Superficie es_ES
dc.subject Implante es_ES
dc.subject Ensayo Clínico Aleatorizado es_ES
dc.title Descontaminación de la superficie del implante mediante el tratamiento quirúrgico de la periimplantitis: una revisión sistemática es_ES
dc.title.alternative Decontamination of the implant surface by surgical treatment of peri-implantitis: a systematic review es_ES
dc.type info:eu-repo/semantics/monograph es_ES
thesis.degree.name Especialista en Periodoncia e Implantología es_ES
thesis.degree.grantor Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira es_ES
thesis.degree.discipline Periodoncia e Implantología es_ES
dc.publisher.country PE es_ES
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.02.14 es_ES
renati.author.dni 72266391
renati.author.dni 72949382
renati.advisor.orcid https://orcid.org/0000-0002-0330-8807 es_ES
renati.advisor.orcid https://orcid.org/0000-0001-5136-6799 es_ES
renati.advisor.dni 10587840
renati.advisor.dni 42204495
renati.type http://purl.org/pe-repo/renati/type#tesis es_ES
renati.level http://purl.org/pe-repo/renati/nivel#tituloSegundaEspecialidad es_ES
renati.discipline 911299 es_ES
renati.juror Málaga Figueroa, Lilian Teresa es_ES
renati.juror Castillo Monzón, Ruth Silvia es_ES
renati.juror Chávez Vereau, Natali es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en el Repositorio


Listar

Panel de Control

Estadísticas